Size analysis of carboxydextran coated superparamagnetic iron oxide particles used as contrast agents of magnetic resonance imaging

被引:37
作者
Chen, D. -X. [1 ,2 ]
Sun, N. [3 ]
Gu, H. -C. [3 ]
机构
[1] Univ Autonoma Barcelona, ICREA, Bellaterra 08193, Spain
[2] Univ Autonoma Barcelona, Dept Fis, Bellaterra 08193, Spain
[3] Shanghai Jiao Tong Univ, Med Inst X, Shanghai 200030, Peoples R China
关键词
CHEMICAL-EXCHANGE MODEL; NANOPARTICLES; RELAXATION; PROFILES;
D O I
10.1063/1.3211307
中图分类号
O59 [应用物理学];
学科分类号
摘要
Superparamagnetic iron oxide particles in commercial products Resovist and SH U555C, used as magnetic resonance imaging contrast agents, are polydispersed and covered with a thick organic coating so that the average particle sizes were reported between 3 and 62 nm with different definitions. It is unclear which size determines the transverse relaxation rate 1/T-2 of water suspensions of such particles. Comparing the measured 1/T-2 and average sizes of different definitions determined from magnetization curve, transmission electron microscopy image, x-ray diffraction, and dynamic light scattering, it is found that the 1/T-2 behavior is basically determined by the diameter of bare single-crystal magnetic particles having the particle-volume-weighted average volume (about 14 or 9 nm for Resovist or SH U555C and is slightly influenced by their thick organic coating. This is explained by the low partial density of the coating substance and the overwhelming water occupation adjacent to magnetic particles. (C) 2009 American Institute of Physics. [doi: 10.1063/1.3211307]
引用
收藏
页数:9
相关论文
共 30 条
[1]  
BATE G, 1980, FERROMAGNETIC MATERI, V2, P427
[2]  
Bean C.P., 1959, J. Appl. Phys., V30, DOI [10.1063/1.2185850, DOI 10.1063/1.2185850]
[3]   The utility of superparamagnetic contrast agents in MRI: theoretical consideration and applications in the cardiovascular system [J].
Bjornerud, A ;
Johansson, L .
NMR IN BIOMEDICINE, 2004, 17 (07) :465-477
[4]  
BLOCH F, 1946, PHYS REV, V70, P460, DOI 10.1103/PhysRev.70.460
[5]   T2-shortening by strongly magnetized spheres:: A chemical exchange model [J].
Brooks, RA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :388-391
[6]   On T2-shortening by weakly magnetized particles:: The chemical exchange model [J].
Brooks, RA ;
Moiny, F ;
Gillis, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :1014-1020
[7]   DISTRIBUTION OF FIELDS FROM RANDOMLY PLACED DIPOLES - FREE-PRECESSION SIGNAL DECAY AS RESULT OF MAGNETIC GRAINS [J].
BROWN, RJ .
PHYSICAL REVIEW, 1961, 121 (05) :1379-+
[8]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[9]   Size determination of superparamagnetic nanoparticles from magnetization curve [J].
Chen, D. -X. ;
Sanchez, A. ;
Taboada, E. ;
Roig, A. ;
Sun, N. ;
Gu, H. -C. .
JOURNAL OF APPLIED PHYSICS, 2009, 105 (08)
[10]   Size-independent residual magnetic moments of colloidal Fe3O4-polystyrene nanospheres detected by ac susceptibility measurements [J].
Chen, Du-Xing ;
Sanchez, Alvaro ;
Xu, Hong ;
Gu, Hongchen ;
Shi, Donglu .
JOURNAL OF APPLIED PHYSICS, 2008, 104 (09)