Development of multichannel devices with an array of electrospray tips far high-throughput mass spectrometry

被引:94
作者
Liu, HH
Felten, C
Xue, QF
Zhang, BL
Jedrzejewski, P
Karger, BL
Foret, F [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
关键词
D O I
10.1021/ac000115l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The basic principles of multichannel devices with an array of electrospray tips for high-throughput infusion electrospray ionization mass spectrometry (ESI-MS) have been developed. The prototype plastic devices were fabricated by casting from a solvent-resistant resin, The sample wells on the device were arranged in the format of the standard 96-microtiter well plate, with each sample well connected to an independent electrospray exit port via a microchannel with imbedded electrode, A second plastic plate with distribution microchannels was employed as a cover plate and pressure distributor. Nitrogen gas was used to pressurize individual wells for transport of sample into the electrospray exit port. The design of independent microchannels and electrospray exit ports allowed very high throughput and duty cycle, as well as elimination of any potential sample carryover. The device was placed on a computer-controlled translation stage for precise positioning of the electrospray exit ports in front of the mass spectrometer sampling orifice. High-throughput EST-MS was demonstrated by analyzing 96 peptide samples in 480 s, corresponding to a potential throughput of 720 samples/h, ils a model application, the device was used for the MS determination of inhibition constants of several inhibitors of HIV-1 protease.
引用
收藏
页码:3303 / 3310
页数:8
相关论文
共 48 条
[1]   USE OF A 96-WELL MICROPLATE READER FOR MEASURING ROUTINE ENZYME-ACTIVITIES [J].
ASHOUR, MBA ;
GEE, SJ ;
HAMMOCK, BD .
ANALYTICAL BIOCHEMISTRY, 1987, 166 (02) :353-360
[2]  
Bateman KP, 1997, RAPID COMMUN MASS SP, V11, P307
[3]  
BERRY COA, 1993, BIOTECHNIQUES, V14, P340
[4]   Microfluidic devises connected to fused-silica capillaries with minimal dead volume [J].
Bings, NH ;
Wang, C ;
Skinner, CD ;
Colyer, CL ;
Thibault, P ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3292-3296
[5]  
Chen S, 1999, RAPID COMMUN MASS SP, V13, P1980, DOI 10.1002/(SICI)1097-0231(19991030)13:20<1980::AID-RCM741>3.0.CO
[6]  
2-C
[7]  
Desai A, 1997, TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P927, DOI 10.1109/SENSOR.1997.635254
[8]   Application of capillary electrophoresis electrospray ionization mass spectrometry in the determination of molecular diversity [J].
Dunayevskiy, YM ;
Vouros, P ;
Wintner, EA ;
Shipps, GW ;
Carell, T ;
Rebek, J .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (12) :6152-6157
[9]  
Felleisen R, 1996, BIOTECHNIQUES, V20, P616
[10]   A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry [J].
Figeys, D ;
Ning, YB ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3153-3160