Technique and pitfalls of ultrasound-guided core-needle biopsy of the breast

被引:28
作者
Harvey, JA [1 ]
Moran, RE [1 ]
DeAngelis, GA [1 ]
机构
[1] Univ Virginia, Dept Radiol, Charlottesville, VA 22908 USA
关键词
D O I
10.1016/S0887-2171(00)90030-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
When using ultrasound guidance to perform core-needle biopsy, the curvature of the breast can be used to advantage. By entering the breast from the periphery, chest wall injury is avoided and needle visualization is improved. Visualization of the needle is expedited by bringing the needle to the lesion by using a gentle sweeping motion while keeping the transducer relatively fixed in position. Standard techniques can be modified for difficult lesions, such as those that are mobile, deep, small, or in a large breast. Careful correlation with the mammogram will insure biopsy of the corresponding sonographic lesion. Although complications are uncommon, hematoma or infection may occur after the procedure. With practice, application of standard and modified techniques can result in efficient and accurate ultrasound-guided percutaneous core-needle biopsy of the breast. Copyright (C) 2000 by W.B. Saunders Company.
引用
收藏
页码:362 / 374
页数:13
相关论文
共 36 条
[1]   Radial scar of the breast: Radiologic-pathologic correlation in 22 cases [J].
Alleva, DQ ;
Smetherman, DH ;
Farr, GH ;
Cederbom, GJ .
RADIOGRAPHICS, 1999, 19 :S27-S35
[2]  
American College of Radiology, 1993, BREAST IMAGING REPOR
[3]   Sonographically guided percutaneous interventions of the breast using a steerable ultrasound beam [J].
Baker, JA ;
Soo, MS ;
Mengoni, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (01) :157-159
[4]   TEMPLATE-GUIDED BREAST US [J].
BREM, RF ;
GATEWOOD, OMB .
RADIOLOGY, 1992, 184 (03) :872-874
[5]   CT AND SONOGRAPHICALLY GUIDED NEEDLE-BIOPSY - CURRENT TECHNIQUES AND NEW INNOVATIONS [J].
CHARBONEAU, JW ;
READING, CC ;
WELCH, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (01) :1-10
[6]   Usefulness of tissue marker clips in patients undergoing neoadjuvant chemotherapy for breast cancer [J].
Dash, N ;
Chafin, SH ;
Johnson, RR ;
Contractor, FM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (04) :911-917
[7]   Are malignant cells displaced by large-gauge needle core biopsy of the breast? [J].
Diaz, LK ;
Wiley, EL ;
Venta, LA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (05) :1303-1313
[8]  
DORSI CJ, 1989, SEMIN ULTRASOUND CT, V10, P132
[10]  
FORNAGE BD, 1992, RADIOL CLIN N AM, V30, P167