Automatic registration and alignment on a template of cardiac stress and rest reoriented SPECT images

被引:62
作者
Declerck, J
Feldmar, J
Goris, ML
Betting, F
机构
[1] INRIA, Epidaure Grp, F-06902 Sophia Antipolis, France
[2] Stanford Univ Hosp, Div Nucl Med, Stanford, CA 94305 USA
关键词
B-splines; myocardial perfusion imaging; nonrigid matching; SPECT;
D O I
10.1109/42.650870
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Single photon emission computed tomography (SPECT) imaging with Tl-201 or Tc-99m agent is used to assess the location or the extent of myocardial infarction or ischemia, A method is proposed to decrease the effect of operator variability in the visual or quantitative interpretation of scintigraphic myocardial perfusion studies, To effect this, the patient's myocardial images (target cases) are registered automatically over a template image, utilizing a nonrigid transformation, The intermediate steps are: 1) Extraction of feature points in both stress and rest three-dimensional (3-D) images, The images are resampled in a polar geometry to detect edge points, which in turn are filtered by the use of a priori constraints. The remaining feature points are assumed to be points on the edges of the left ventricular myocardium, 2) Registration of stress and rest images with a global affine transformation, The matching method is an adaptation of the iterative closest point algorithm, 3) Registration and morphological matching of both stress and rest images on a template using a nonrigid local spline transformation following a global affine transformation, 4) Resampling of both stress and rest images in the geometry of the template. Optimization of the method was performed on a database of 40 pairs of stress and rest images selected to obtain a wide variation of images and abnormalities, Further testing was performed on 250 cases selected from the same database on the basis of the availability of angiographic results and patient stratification.
引用
收藏
页码:727 / 737
页数:11
相关论文
共 37 条
[1]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[2]  
CALDWELL J, 1985, CIRCULATION, V70, P1048
[3]  
CAUVIN JC, 1992, EUR J NUCL MED, V19, P1032
[4]   Automatic registration and alignment on a template of cardiac stress & rest SPECT images [J].
Declerck, J ;
Feldmar, J ;
Betting, F ;
Goris, ML .
PROCEEDINGS OF THE IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, 1996, :212-221
[5]  
DECLERCK J, 1996, 2770 INRIA RR
[6]  
DECLERCK J, 2485 INRIA
[7]  
DECLERCK J, 1995, LECT NOTES COMPUTER, V905, P153
[8]  
DIPASQUALE EE, 1988, CIRCULATION, V77, P316
[9]  
FARIN G, 1989, CURVES SURFACES COMP
[10]   Rigid, affine and locally affine registration of free-form surfaces [J].
Feldmar, J ;
Ayache, N .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1996, 18 (02) :99-119