The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study

被引:116
作者
Resch, T [1 ]
Malina, M [1 ]
Lindblad, B [1 ]
Malina, J [1 ]
Brunkwall, J [1 ]
Ivancev, K [1 ]
机构
[1] Malmo Univ Hosp, Dept Radiol, S-20502 Malmo, Sweden
关键词
stent grafts; fixation; migration; aortic aneurysm; therapy;
D O I
10.1053/ejvs.1999.0991
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: to study the proximal fixation of different aortic stent grafts in comparison to a hand-sewn anastomis. Design: experimental study. Material: the infrarenal aorta of 16 human cadavers were exposed, left in situ and transected 3 cm above the aortic bifurcation to mimic an infrarenal aortic neck. Stent grafts were deployed through a sheath 5 cm into the aorta. Ancure, Talent, Vanguard, Zenith and a Palmaz based stent graft were assessed. In addition a polyester graft was anastomosed to the aorta by running sutures. Distal force was applied to the grafts in increments of 0.5 Newton until the stent grafts were completely dislodged from the aorta. The displacement force (DF) was thereby determined. Results: a force of 150 N (140-160) applied to the hand-sewn graft resulted in tearing of the aorta, without breakage of the sutures. The median displacement force was for Talent 4.5 N (1.3-5.5), Vanguard 9.0 N (3.5-12), Ancure 12.5 N (12-14), Zenith 24 N (23-26.5) and Palmaz 25 N (17-25). Ballooning the stent after deployment improved fixation in some cases. Conclusions: a sutured anastomosis fixates a graft better than any stent design tested. Hooks and barbs improve the fixation of self-expandable stents. Balloon dilatation of the proximal stent after deployment might increase fixation further. Balloon expandable stents seem to provide good fixation without the use of hooks and barbs.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 22 条
[1]  
BERGERON P, 1998, J ENDOVASC SURG, V4, P124
[2]   Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms [J].
Blum, U ;
Voshage, G ;
Lammer, J ;
Beyersdorf, F ;
Tollner, D ;
Kretschmer, G ;
Spillner, G ;
Polterauer, P ;
Nagel, G ;
Holzenbein, T ;
Thurnher, S ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) :13-20
[3]   Evaluation of the risks of using an oversized balloon catheter in the human infrarenal abdominal aorta [J].
Chaufour, X ;
White, GH ;
Hambly, BD ;
Yu, W ;
May, J ;
Harris, JP ;
Stephen, MS .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 16 (02) :142-147
[4]  
GAINES P, 1998, RETA ENDOVASCULAR AB
[5]  
GOULD D, 1999, FOLLOW UP ABDOMINAL
[6]  
HARRIS P, 1999, ENDOLEAKS ASS RISK F
[7]   Endoluminal repair of abdominal aortic aneurysms - A critical reappraisal after a three-and-a-half year experience [J].
Ivancev, K ;
Resch, T ;
Brunkwall, J ;
Lindh, M ;
Malina, M ;
Nyman, U ;
Lindblad, B .
SEMINARS IN INTERVENTIONAL RADIOLOGY, 1998, 15 (01) :97-108
[8]   Experimental assessment of proximal stent-graft (InterVascular™) fixation in human cadaveric infrarenal aortas [J].
Lambert, AW ;
Williams, DJ ;
Budd, JS ;
Horrocks, M .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 17 (01) :60-65
[9]   The Perth HLB bifurcated endoluminal graft: A review of the experience and intermediate results [J].
Lawrence-Brown, M ;
Sieunarine, K ;
Hartley, D ;
van Schie, G ;
Goodman, MA ;
Prendergast, FJ .
CARDIOVASCULAR SURGERY, 1998, 6 (03) :220-225
[10]  
Malina M, 1998, J ENDOVASC SURG, V5, P310, DOI 10.1583/1074-6218(1998)005<0310:EAEWSW>2.0.CO