Interpretation of periapical lesions comparing conventional, direct digital, and telephonically transmitted radiographic images

被引:34
作者
Mistak, EJ
Loushine, RJ
Primack, PD
West, LA
Runyan, DA
机构
[1] USA, Hanau, Germany
[2] USA, Dent Activ, Endodontic Residency Program, Off Surgeon Gen, Ft Gordon, GA 30905 USA
关键词
D O I
10.1016/S0099-2399(98)80110-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to evaluate direct digital radiography (DDR) and telephonically transmitted images versus conventional radiography in the interpretation of artificial periapical bone lesions. Five teeth were chosen from four cadaver jaw specimens. Three types of DDR images were evaluated: DDR stored images, DDR transmitted images, and DDR reversed images. A total of 150 DDR computer monitor images and 56 D-speed film images were evaluated by three endodontists and one endodontic graduate student. The Wilcoxon signed-ranks test was used for statistical analyses of the results. DDR reversed images were statistically inferior to DDR stored images, DDR transmitted images, and conventional radiography images (p < 0.0001). There were no statistically significant differences between DDR stored images, DDR transmitted images, and conventional film images in the ability of the evaluator to identify artificial periapical bone lesions (p > 0.05).
引用
收藏
页码:262 / 266
页数:5
相关论文
共 11 条
[1]   EVALUATION OF THE NEW RADIOVISIOGRAPHY SYSTEM IMAGE QUALITY [J].
BENZ, C ;
MOUYEN, F .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1991, 72 (05) :627-631
[2]   DIGITAL RADIOLOGY FACTS AND FICTIONS [J].
DUNN, SM ;
KANTOR, ML .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1993, 124 (12) :39-47
[3]   RADIOVISIOGRAPHY VERSUS CONVENTIONAL RADIOGRAPHY FOR DETECTION OF SMALL INSTRUMENTS IN ENDODONTIC LENGTH DETERMINATION .1. IN-VITRO EVALUATION [J].
ELLINGSEN, MA ;
HARRINGTON, GW ;
HOLLENDER, LG .
JOURNAL OF ENDODONTICS, 1995, 21 (06) :326-331
[4]   DIRECT DIGITAL RADIOGRAPHY FOR THE DETECTION OF PERIODONTAL BONE-LESIONS [J].
FURKART, AJ ;
DOVE, SB ;
MCDAVID, WD ;
NUMMIKOSKI, P ;
MATTESON, S .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 74 (05) :652-660
[5]   INTERPRETATION OF ENDODONTIC FILE LENGTHS USING RADIO VISIOGRAPHY [J].
LEDDY, BJ ;
MILES, DA ;
NEWTON, CW ;
BROWN, CE .
JOURNAL OF ENDODONTICS, 1994, 20 (11) :542-545
[6]   PRESENTATION AND PHYSICAL EVALUATION OF RADIO VISIOGRAPHY [J].
MOUYEN, F ;
BENZ, C ;
SONNABEND, E ;
LODTER, JP .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 68 (02) :238-242
[7]   SENS-A-RAY - A NEW SYSTEM FOR DIRECT DIGITAL INTRAORAL RADIOGRAPHY [J].
NELVIG, P ;
WING, K ;
WELANDER, U .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1992, 74 (06) :818-823
[8]   COMPARISON OF RADIOVISIOGRAPHY WITH RADIOGRAPHIC FILM IN ROOT LENGTH DETERMINATION [J].
ONG, EY ;
FORD, TRP .
INTERNATIONAL ENDODONTIC JOURNAL, 1995, 28 (01) :25-29
[9]   Interpretation of chemically created lesions using direct digital imaging [J].
Tirrell, BC ;
Miles, DA ;
Brown, CE ;
Legan, JJ .
JOURNAL OF ENDODONTICS, 1996, 22 (02) :74-78
[10]  
VANDRE RH, 1995, ORAL SURG ORAL MED O, V80, P471