A validated chiral HPLC method for the enantiomeric separation of Linezolid on amylose based stationary phase

被引:26
作者
Narayana, CL
Suresh, T
Rao, SM
Dubey, PK
Babu, JM
机构
[1] Dr Reddys Labs Ltd, Discovery Res, Hyderabad 500016, Andhra Pradesh, India
[2] Dr Reddys Labs Ltd, Custom Chem Serv, Hyderabad 500016, Andhra Pradesh, India
[3] JNT Univ, Dept Chem, Hyderabad 500872, Andhra Pradesh, India
关键词
linezolid; enantiomeric separation; chiral assay; preparative chiral HPLC; F-test; limit of detection; limit of quantification;
D O I
10.1016/S0731-7085(03)00031-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two chiral HPLC methods namely method A and method B were developed for the separation of enantiomers of Linezolid. The mobile phases containing hexane, 2-propanol and trifluoro acetic acid (TFA) in the ratio (80:20:0.1, v/v/v); hexane, ethanol and TFA in the ratio (65:35:0.1, v/v/v) were used in method A and method B, respectively. The assay results of the two methods were checked in terms of F-test variance ratio and found to be less than the table value, confirming their good precision. The enantiomeric separation of Linezolid on different chiral stationary phases was investigated. The two enantiomers of Linezoild were well resolved on a Chiralpak AD, an amylose based stationary phase. Preparative chiral HPLC was carried out to obtain pure (+) enantiomer of Linezolid from its racemate. The method A was extensively validated and found to be robust. The chiral assay of Linezolid in bulk and pharmaceutical formulations (tablet) were found to be 100.4+/-0.4 and 101.2+/-1.4%, respectively at 95% confidence interval. The percentage recovery of (+) enantiomer (chiral impurity) was found to be 99.2+/-1.9 at 95% confidence interval. The limit of detection and limit of quantification of (+) enantiomer were found to be 123 and 374 ng/ml, respectively for 10 mul injection volume. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:21 / 28
页数:8
相关论文
共 10 条
  • [1] Barrett J F, 2000, Curr Opin Investig Drugs, V1, P181
  • [2] Determination of linezolid in human serum and urine by high-performance liquid chromatography
    Borner, K
    Borner, E
    Lode, H
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2001, 18 (03) : 253 - 258
  • [3] DEAN LS, 1997, ANTIMICROB AGENTS CH, V10, P2132
  • [4] A new and rapid method for monitoring the new oxazolidinone antibiotic linezolid in serum and urine by high performance liquid chromatography-integrated sample preparation
    Ehrlich, M
    Trittler, R
    Daschner, FD
    Kümmerer, K
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2): : 373 - 377
  • [5] GEOFFREY WP, 1999, J PHARM BIOMED ANAL, V20, P65
  • [6] Gray E.Z., 1997, Expert Opin Investig Drugs, V6, P151, DOI 10.1517/13543784.6.2.151
  • [7] RESOLUTION BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING POLYSACCHARIDE CARBAMATES AND BENZOATES AS CHIRAL STATIONARY PHASES
    OKAMOTO, Y
    KAIDA, Y
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 666 (1-2) : 403 - 419
  • [8] A simple, isocratic high-performance liquid chromatography assay for linezolid in human serum
    Tobin, CM
    Sunderland, J
    White, LO
    MacGowan, AP
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2001, 48 (05) : 605 - 608
  • [9] RESOLUTION OF ENANTIOMERIC AROMATIC ALCOHOLS ON A CELLULOSE TRIBENZOATE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CHIRAL STATIONARY PHASE - A PROPOSED CHIRAL RECOGNITION MECHANISM
    WAINER, IW
    STIFFIN, RM
    SHIBATA, T
    [J]. JOURNAL OF CHROMATOGRAPHY, 1987, 411 : 139 - 151
  • [10] 1995, FED REG 0301, V60, P11260