Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids

被引:90
作者
de Jonge, Robert [1 ]
Brouwer, Rob [1 ]
de Graaf, Marieke T.
Luitwieler, Ronald L. [2 ]
Fleming, Cherina [1 ]
de Frankrijker-Merkestijn, Magda [1 ]
Smitt, Peter A. E. Sillevis
Boonstra, Joke G. [1 ]
Lindemans, Jan [1 ]
机构
[1] Univ Med Ctr Rotterdam, Dept Clin Chem, Erasmus MC, NL-3015 CE Rotterdam, Netherlands
[2] St Franciscus Gasthuis, Rotterdam, Netherlands
关键词
body fluid; cerebrospinal fluid; erythrocytes; hemocytometry; leukocytes; Sysmex XE-5000; FLOW-CYTOMETRIC ANALYSIS; BLOOD-CELLS; DIFFERENTIAL LEUKOCYTE; AUTOMATED-ANALYSIS; SYNOVIAL-FLUID; UPDATE; WHITE;
D O I
10.1515/CCLM.2010.108
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
100118 [医学信息学]; 100208 [临床检验诊断学];
摘要
Background: We evaluated the body fluid (BF) mode on the new Sysmex XE-5000 analyzer. Methods: Red (RBC) and white blood cell (WBC) (differential) counts of BFs (139 patient samples and 87 normal samples) were measured and compared to the Fuchs-Rosenthal chamber and stained cytospin slides. Results: Extended cell counting using the BF mode was noted to have an improved WBC detection limit (CV20%) of 10x10(6)/L. Excellent agreement with the manual method was observed for most BFs [mean bias +2 to 6x10(6)/L for cerebrospinal fluid (CSF) and -1 to 12x10(6)/L for other fluids]. In CSF, the BF-mode counted more WBC (polymorphic nuclear cells) compared with the manual method (mean bias +5 to 6x10(6)/L), especially in samples with low cell counts (<20x10(6)/L). Carry over was negligible (mostly <0.17%) and linearity was excellent (mean bias <5%). The reference ranges for CSF (n=87) were RBC 0x10(6)/L, WBC and mononuclear <7x10(6)/L, and polymorph nucleated cells <3x10(6)/L. Conclusions: The BF mode on the Sysmex XE-5000 offers rapid and accurate RBC and WBC (differential) counts in clinically relevant concentration ranges in CSF and other fluids. In addition, the exclusion of high fluorescent cells, such as mesothelial cells and macrophages from WBC counting may reduce the number of manual analyses in pleural fluids and ascites. Clin Chem Lab Med 2010;48:665-75.
引用
收藏
页码:665 / 675
页数:11
相关论文
共 22 条
[1]
Angeloni S, 2003, AM J GASTROENTEROL, V98, P1844, DOI 10.1111/j.1572-0241.2003.07620.x
[2]
Aulesa C, 2003, Lab Hematol, V9, P214
[3]
Automated counting of white and red blood cells in the cerebrospinal fluid [J].
Aune, MW ;
Sandberg, S .
CLINICAL AND LABORATORY HAEMATOLOGY, 2000, 22 (04) :203-210
[4]
Automated flow cytometric analysis of blood cells in cerebrospinal fluid - Analytic performance [J].
Aune, MW ;
Becker, JL ;
Brugnara, C ;
Canfield, W ;
Dorfman, DM ;
Fiehn, W ;
Fischer, G ;
Fitzpatrick, P ;
Flaming, TH ;
Henriksen, HK ;
Kunicka, JE ;
Lackner, KJ ;
Minchello, E ;
Mullenix, PA ;
Myers, M ;
Petersen, A ;
Ternstrom, W ;
Wilson, S .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 121 (05) :690-700
[5]
Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid [J].
Boer, Klas ;
Deufel, Thomas ;
Reinhoefer, Mike .
CLINICAL BIOCHEMISTRY, 2009, 42 (7-8) :684-691
[6]
LYSIS OF ERYTHROCYTES AND LEUKOCYTES IN TRAUMATIC LUMBAR PUNCTURES [J].
CHOW, G ;
SCHMIDLEY, JW .
ARCHIVES OF NEUROLOGY, 1984, 41 (10) :1084-1085
[7]
Variations in pleural fluid WBC count and differential counts with different sample containers and different methods [J].
Conner, BD ;
Lee, YCG ;
Branca, P ;
Rogers, JT ;
Rodriguez, RM ;
Light, RW .
CHEST, 2003, 123 (04) :1181-1187
[8]
Automated counting of white blood cells in synovial fluid [J].
de Jonge, R ;
Brouwer, R ;
Smit, M ;
de Frankrijker-Merkestijn, M ;
Dolhain, RJEM ;
Hazes, JMW ;
van Toorenenbergen, AW ;
Lindemans, J .
RHEUMATOLOGY, 2004, 43 (02) :170-173
[9]
Automated analysis of pleural fluid total and differential leukocyte counts with the Sysmex XE-2100 [J].
de Jonge, Robert ;
Brouwer, Rob ;
van Rijn, Marcel ;
van Acker, Bernadette A. C. ;
Otten, Henk J. A. M. ;
Lindemans, Jan .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (11) :1367-1371
[10]
A STANDARDIZED PROTOCOL FOR FLOW CYTOMETRIC ANALYSIS OF CELLS ISOLATED FROM CEREBROSPINAL-FLUID [J].
DUX, R ;
KINDLERROHRBORN, A ;
ANNAS, M ;
FAUSTMANN, P ;
LENNARTZ, K ;
ZIMMERMANN, CW .