Self monitoring of blood glucose - A survey of diabetes UK members with type 2 diabetes who use SMBG

被引:19
作者
Barnard K.D. [1 ]
Young A.J. [2 ]
Waugh N.R. [3 ]
机构
[1] NIHR Evaluation Trials and Studies Coordinating Centre, University of Southampton, Chilworth, Southampton SO16 7NS, Southampton Science Park
[2] Wessex Institute, University of Southampton, Chilworth, Southampton SO16 7NS, Southampton Science Park
[3] Department of Public Health, University of Aberdeen, Foresterhill
关键词
Physical Activity; Blood Glucose; Blood Glucose Level; Hypoglycaemic Episode; Range Reading;
D O I
10.1186/1756-0500-3-318
中图分类号
学科分类号
摘要
Background. Aim - to survey members of Diabetes UK who had Type 2 diabetes and who used self monitoring of blood glucose (SMBG), to elicit their views on its usefulness in the management of their diabetes, and how they used the results. A questionnaire was developed for the Diabetes UK website. The questionnaire was posted on the Diabetes UK website until over 500 people had responded. Questions asked users to specify the benefits gained from SMBG, and how these benefits were achieved. We carried out both quantitative analysis and a thematic analysis for the open ended free-text questions. Findings. 554 participants completed the survey, of whom 289 (52.2%) were male. 20% of respondents were recently diagnosed (< 6 months). Frequency of SMBG varied, with 43% of participants testing between once and four times a day and 22% testing less than once a month or for occasional periods. 80% of respondents reported high satisfaction with SMBG, and reported feeling more 'in control' of their diabetes management using it. The most frequently reported use of SMBG was to make adjustments to food intake or confirm a hyperglycaemic episode. Women were significantly more likely to report feelings of guilt or self-chastisement associated with out of range readings (p = < .001). Conclusion. SMBG was clearly of benefit to this group of confirmed users, who used the results to adjust diet, physical activity or medications. However many individuals (particularly women) reported feelings of anxiety and depression associated with its use. © 2009 Barnard et al; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 9 条
[1]  
Clar C., Barnard K., Cummins E., Royle P., Waugh N., Self-monitoring of blood glucose in type 2 diabetes: Systematic review, Health Technology Assessment, 14, (2010)
[2]  
Self Monitoring of Blood Glucose in Non-insulin-treated Type 2 Diabetes, (2010)
[3]  
Barnard K.D., Loveman E., Are there benefits to self-monitoring of blood glucose in type 2 diabetes?, Practical Diabetes International, 25, 5, pp. 170-171, (2008)
[4]  
O'Kane M.J., Bunting B., Copeland M., Coates V.E., Efficacy of self monitoring of blood glucose in patients with newly diagnosed type 2 diabetes (ESMON study): Randomised controlled trial, BMJ, 336, pp. 1174-7, (2008)
[5]  
Helsier M., Piette J.D., Spencer M., Keiffer E., Vijan S., The Relationship between Knowledge of Recent HbA<sub>1c</sub>Values and Diabetes Care Understanding and Self-Management, Diabetes Care, 28, 4, pp. 816-822, (2005)
[6]  
Davis W.A., Bruce D.G., Davis T.M., Is self-monitoring of blood glucose appropriate for all type 2 diabetic patients? the Fremantle Diabetes Study, Diabetes Care, 29, pp. 1764-70, (2006)
[7]  
Karter A.J., Parker M.M., Moffet H.H., Spence M.M., Chan J., Ettner S.L., Et al., Longitudinal study of new and prevalent use of self-monitoring of blood glucose, Diabetes Care, 29, pp. 1757-63, (2006)
[8]  
Martin S., Schneider B., Heinemann L., Lodwig V., Kurth H.J., Kolb H., Et al., Self-monitoring of blood glucose in type 2 diabetes and long-term outcome: An epidemiological cohort study, Diabetologia, 49, pp. 271-8, (2006)
[9]  
Simon J., Gray A., Clarke P., Wade A., Neil A., Farmer A., Et al., Cost effectiveness of self monitoring of blood glucose in patients with non-insulin treated type 2 diabetes: Economic evaluation of data from the DiGEM trial, BMJ, 336, 7654, pp. 1177-1180, (2008)