Using out of office blood pressure monitoring in the management of hypertension

被引:13
作者
Verdecchia P. [1 ]
机构
[1] Cardiologia e Fisiopatologia Cardiovascolare, Università di Perugia, Policlinico Monteluce, 06122 Perugia PG
关键词
Ambulatory Blood Pressure; Blood Pressure Monitoring; Ambulatory Blood Pressure Monitoring; Target Organ Damage; Lacidipine;
D O I
10.1007/s11906-001-0057-z
中图分类号
学科分类号
摘要
Self-measurement of blood pressure (BP) and 24-hour ambulatory BP monitoring (ABPM) are increasingly used in order to improve cardiovascular risk stratification over and beyond traditional methods, including sphygmomanomet-ric BP measurement. Self-measured BP has the advantage of being cheap, quite representative of the usual BP over long periods of time, and devoid of the "white coat" effect. Only a few data exist on the prognostic value of self-measured B P. Most of the outcome studies with 24-hour ABPM have been conducted in patients with essential hypertension who were untreated at the time of execution of ABPM. Cardiovascular risk showed a direct association with ambulatory BP and an inverse association with the degree of BP reduction from day to night. White coat hypertension versus ambulatory hypertension and dippers versus nondippers are two classifications based on arbitrary operational risk categories. ABPM may be valuable for refining cardiovascular risk stratification in untreated subjects with office hypertension, as well as those with resistant hypertension. Copyright © 2001 by Current Science Inc.
引用
收藏
页码:400 / 405
页数:5
相关论文
共 43 条
[1]  
Riva Rocci S., Tecnica sfigmomanometrica, Gazzetta Med Torino, 48, pp. 161-172, (1897)
[2]  
Armitage P., Rose G.A., The variability of measurements of casual blood pressure. 1. A laboratory study, Clin Sci, 30, pp. 325-335, (1966)
[3]  
Mancia G., Bertinieri G., Grassi G., Et al., Effects of blood pressure measured by the doctor on patient's blood pressure and heart rate, Lancet, 2, pp. 695-698, (1983)
[4]  
Pickering T.G., Self-monitoring of blood pressure, Blood Pressure Monitoring in Cardiovascular Medicine and Therapeutics, pp. 3-27, (2000)
[5]  
Nordmann A., Frach B., Walker T., Et al., Reliability of patients measuring blood pressure at home: Prospective observational study, BMJ, 319, (1999)
[6]  
Association for the advancement of medical instrumentation: American national standard. Electronic or automated sphygmoma-nometers, ANSI/AAMI SP 10-1992, (1993)
[7]  
O'Brien E., Petrie J., Littler W.A., Et al., The British hypertension society protocol for the evaluation of blood pressure measuring devices, J Hypertens, 11, SUPPL. 2, (1993)
[8]  
O'Brien E., Waeber B., Parati G., Et al., Blood pressure measuring devices: Recommendations of the european society of hypertension, BMJ, 322, pp. 531-536, (2001)
[9]  
Asmar R., Zanchetti A., Guidelines for the use of self-blood pressure monitoring: A summary report of the first international consensus conference, J Hypertens, 18, pp. 493-508, (2000)
[10]  
Tsuji I., Imai Y., Nagai K., Et al., Proposal of reference values for home blood pressure measurement: Prognostic criteria based on a prospective observation of the general population in ohasama, Japan, Am J Hypertens, 10, pp. 409-418, (1997)