Analysis method of noise power spectrum for medical monochrome liquid crystal displays.

被引:10
作者
Ichikawa K. [1 ]
Kodera Y. [1 ]
Nishimura A. [1 ]
Hasegawa M. [1 ]
Kimura N. [1 ]
Takemura A. [1 ]
Matsubara K. [1 ]
机构
[1] Graduate School of Medical Science, Kanazawa University, Kanazawa, Ishikawa
关键词
Liquid crystal display (LCD); Noise power spectrum (NPS); Fourier analysis; Digital camera;
D O I
10.1007/s12194-008-0029-y
中图分类号
学科分类号
摘要
We investigated methods of analyzing the noise power spectrum (NPS) measurement for medical liquid crystal displays (LCDs). Uniform images displayed on the LCDs were imaged with a high-performance digital camera equipped with a close-up lens, and then the NPSs were calculated from the image data by means of several analysis methods. In a method using the 2D fast Fourier transform (FFT) with a 256 x 256 pixels data segment (basic method), we examined the efficacy of a background trend correction (BTC) and a Hanning windowing process used for reducing the spectral estimation errors in the Fourier analysis. To improve the frequency resolution of the basic method, we examined two 2D FFT methods by using 512 x 512 and 1024 x 1024 pixel segments. In addition, we studied a 1D FFT method with 1024-point 1D noise profiles (1D method). In these three methods, the BTC by a second-order polynomial fit and Hanning windowing were commonly applied. A 3-mega-pixel (MP) and a 5-MP monochrome LCD were employed for evaluating the respective methods. Also, a prototype 5-MP LCD equipped with a new anti-reflection surface-coated panel was compared with the conventional 5-MP LCD. The Hanning windowing process was indispensable for avoiding the spectral leakage errors caused by the pixel structures of the LCD. Sufficient frequency resolution was obtained by the 2D FFT method with the 1024 x 1024 pixels segments and the 1D method. The method which provided the most reliable NPSs was the 1D method, with which the BTC was achieved successfully.
引用
收藏
页码:201 / 207
页数:6
相关论文
共 29 条
[1]  
Blume H(2003)Characterization of liquid crystal displays for medical images Part 2 Proc SPIE 5029 449-73
[2]  
Steven P(2004)Noise in flat-panel displays with subpixel structure Med Phys 31 715-23
[3]  
Ho A(2006)Resolution and noise measurements of five CRT and LCD medical displays Med Phys 33 308-19
[4]  
Stevens F(2005)Evaluation of and compensation for spatial noise of LCDs in medical applications Med Phys 32 578-87
[5]  
Abileah A(1986)Investigation of basic imaging properties in digital radiography. 7. Noise Wiener spectra of II-TV digital imaging systems Med Phys 31 131-8
[6]  
Robinson S(1998)Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology Med Phys 25 614-28
[7]  
Badano A(undefined)undefined undefined undefined undefined-undefined
[8]  
Gagne R(undefined)undefined undefined undefined undefined-undefined
[9]  
Jennings R(undefined)undefined undefined undefined undefined-undefined
[10]  
Drilling S(undefined)undefined undefined undefined undefined-undefined