Load-bearing behavior of a simulated craniofacial structure fabricated from a hydroxyapatite cement and bioresorbable fiber-mesh

被引:32
作者
Von Gonten A.S. [1 ]
Kelly J.R. [2 ,3 ]
Antonucci J.M. [2 ]
机构
[1] Department of Prosthodontics, Naval Dental School, Bethesda, MD USA
[2] Dental and Medical Materials Group, Natl. Inst. of Std. and Technology, Gaithersburg, MD
[3] Dental and Medical Materials Group, Gaithersburg, MD 20899-8545, 100 Bureau Drive
基金
美国国家卫生研究院;
关键词
Tensile Strength; Fracture Toughness; PMMA; Methacrylate; Hydroxyapatite;
D O I
10.1023/A:1008992900829
中图分类号
学科分类号
摘要
Calcium phosphate cements (CPC) have proven successful in the repair of small, non-stress bearing skeletal defects. These cements do not have sufficient tensile strength or fracture toughness to allow their use in stress-bearing applications. It was hypothesized that a bioresorbable fiber mesh would improve the load-bearing behavior of shell structures fabricated of CPC. This study used a biaxial flexure fixture to compare the work-to-fracture values of discs made of: (1) CPC; (2) CPC reinforced with a bioresorbable two-dimensionally oriented poly(glactin) fiber-mesh; and (3) poly(methyl methacrylate) (PMMA) that were immersed in a serum-like solution for 0-28 days. CPC-mesh and PMMA discs were indistinguishable at 0, 1 and 7 days, based on work-to-fracture data. CPC and CPC-mesh discs were indistinguishable at day 28, because of fiber hydrolysis. The knitted fiber-mesh was effective in improving load-bearing behavior of a calcium phosphate cement for potential structural repair of bone defects. (C) 2000 Kluwer Academic Publishers.; Calcium phosphate cements (CPC) have proven successful in the repair of small, non-stress bearing skeletal defects. These cements do not have sufficient tensile strength or fracture toughness to allow their use in stress-bearing applications. It was hypothesized that a bioresorbable fiber mesh would improve the load-bearing behavior of shell structures fabricated of CPC. This study used a biaxial flexure fixture to compare the work-to-fracture values of discs made of: (1) CPC; (2) CPC reinforced with a bioresorbable two-dimensionally oriented poly(glactin) fiber-mesh; and (3) poly(methyl methacrylate) (PMMA) that were immersed in a serum-like solution for 0-28 days. CPC-mesh and PMMA discs were indistinguishable at 0, 1 and 7 days, based on work-to-fracture data. CPC and CPC-mesh discs were indistinguishable at day 28, because of fiber hydrolysis. The knitted fiber-mesh was effective in improving load-bearing behavior of a calcium phosphate cement for potential structural repair of bone defects.
引用
收藏
页码:95 / 100
页数:5
相关论文
共 18 条
[1]
Kline D.G., Arch. Surg., 91, (1965)
[2]
Nussbaum C.E., Maurer P.K., McDonald J.V., J. Neurosurg., 71, (1989)
[3]
Beumer J., Firtell D.N., Curtis T.A., J. Prosthet. Dent., 42, (1979)
[4]
Ronderos J.F., Wiles D.A., Ragan F.A., Et al., Surg. Neurol., 37, (1992)
[5]
Costantino P.D., Friedman C.D., Jones K., Chow L.C., Sisson G.A., Plant. Reconstr. Surg., 90, (1992)
[6]
Costantino P.D., Friedman C.D., Otolaryngol. Clin. North Amer., 27, (1994)
[7]
Isaksson S., Swed. Dent. J. Suppl., 84, (1992)
[8]
Brown P.W., Constantz B., Proceedings, Materials Research Society Meeting, (1994)
[9]
Chow L.C., Takagi S., Costantino P.D., Friedman C.D., Mater. Res. Soc. Symp. Proc., 179, (1991)
[10]
Fukase Y., Eanes E.D., Takagi S., Chow L.C., Brown W.E., J. Dent. Res., 69, (1990)