The role of supplemental translaminar screws in anterior lumbar interbody fixation: A biomechanical study

被引:65
作者
Rathonyi G.C. [1 ]
Oxland T.R. [2 ,3 ]
Gerich U. [2 ]
Grassmann S. [2 ]
Nolte L.-P. [2 ]
机构
[1] National Center for Spinal Disorders, Semmelweis University, Budapest
[2] Maurice E. Muller Inst. for Biomech., University of Bern, Bern
[3] Department of Orthopaedics, University of British Columbia, Vancouver, BC V5Z 4E3
关键词
Biomechanics; Implant; Interbody fusion; Stability; Translaminar screws;
D O I
10.1007/s005860050097
中图分类号
学科分类号
摘要
The immediate stabilization provided by anterior interbody cage fixation is often questioned. Therefore, the role of supplementary posterior fixation, particularly minimally invasive techniques such as translaminar screws, is relevant. The purpose of this biomechanical study was to determine the immediate three-dimensional flexibility of the lumbar spine, using six human cadaveric functional spinal units, in four different conditions: (1) intact, (2) fixed with translaminar screws (TLS), (3) instrumented with anterior interbody cage insertion with the BAK system and (4) instrumented with BAK cage with additional TLS fixation. Flexibility was determined in each testing condition by measuring the vertebral motions under applied pure moments (i.e. flexion-extension, bilateral axial rotation, bilateral lateral bending) in an unconstrained manner. Anterior fixation with the BAK alone provided significant stability in flexion and lateral bending. Additional posterior TLS significantly reduced the motion in extension and axial rotation. TLS fixation alone resulted in smaller rotations than BAK fixation in all loading directions. Based on these results, it seems that interbody cage fixation with the BAK system stabilizes the spine in some, but not all, loading directions. The problematic loading directions of extension and axial rotation can be substantially stabilized by using translaminar screw fixation. However, one should emphasize that the degree of stability needed to achieve solid fusion is not known.
引用
收藏
页码:400 / 407
页数:7
相关论文
共 28 条
[1]  
Brantigan J.W., Steffee A.D., A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients, Spine, 18, pp. 2106-2107, (1993)
[2]  
Brodke D.S., Dick J.C., Kunz D.N., McCabe R., Zdeblick T.A., Posterior lumbar interbody fusion. A biomechanical comparison, including a new threaded titanium cage, Spine, 22, pp. 26-31, (1997)
[3]  
Butts M.K., Kuslich S.D., Bechtold J.E., Biomechanical analysis of a new method for spinal interbody fixation, The Winter Annual Meeting of the American Society of Mechanical Engineers, (1987)
[4]  
Fischgrund J., McKay M., Herkowitz H., Brower R., Montgomery D., Kurz L., Degenerative lumbar spondy-lolisthesis with spinal stenosis. A prospective, randomized study, comparing decompression and fusion with and without posterior pedicular instrumentation, Annual Meeting of the International Society for the Study of the Lumbar Spine (ISSLS), (1997)
[5]  
Grob D., Rubeli M., Scheier H.J.G., Dvorak J., Translaminar screw fixation of the lumbar spine, Int Orthop, 16, pp. 223-226, (1992)
[6]  
Guyer D.W., Yuan H.A., Werner F.W., Frederickson B.E., Murphy D., Biomechanical comparison of seven internal fixation devices for the lumbosacral junction, Spine, 12, pp. 569-573, (1987)
[7]  
Heggeness M.H., Esses S.I., Translaminar facet joint screw fixation for lumbar and lumbosacral fusion - A clinical and biomechanical study, Spine, 16, pp. 5266-5269, (1991)
[8]  
Holte D.C., O'Brien J.P., Renton, Anterior lumbar fusion using a hybrid interbody graft. a preliminary radiographic report, Eur Spine J, 3, pp. 32-38, (1994)
[9]  
Jacobs R.R., Montesano P.X., Jackson R.P., Enhancement of lumbar spine fusion by use of translaminar facet joint screws, Spine, 14, pp. 12-15, (1989)
[10]  
Kuslich S.D., Ahern J.W., Dowdle J.D., The BAK method of lumbar interbody fusion-two year follow-up results, Eleventh North American Spine Society Annual Meeting (NASS), (1996)