摘要
Purpose. The aim of this study was to investigate whether it is possible to predict aortic peak enhancement (APE) from the contrast dose and injection rate. Materials and methods. We first undertook an experimental study using a flow phantom that simulates the human circulation. We delivered 90-150 ml of iomeprol-350 at various injection rates and measured the APE values of the simulated aorta. In our clinical study we randomized 20 patients into four groups. In groups A, B, and C the iodine dose per kilogram of body weight (BW) ranged from 450 to 600 mg, and the injection duration was fixed at 30s; group D received 450 mg/kg over 25 s. We then measured APE in all patients at the whole aorta, averaged the three highest values, and took the result as APE. Results. In the phantom study, the decision coefficient for the best-fit equation obtained by multiple regression analysis of the relation between the iodine dose and injection rate and the simulated APE was high (0.93). In the patient study, the predicted APE values almost corresponded with the averaged APE values when we applied the fitness equation. Conclusion. Using our fitness equation, APE on contrast-enhanced computed tomography can be predicted from the iodine dose and the contrast injection rate per patient weight. © Japan Radiological Society 2007.
引用
收藏
页码:14 / 21
页数:7
相关论文
共 20 条
[1]  
Vrtiska T.J., Fletcher J.G., McCollough C.H., State-of-the-art imaging with 64-channel multidetector CT angiography, Perspect Vasc Surg Endovasc Ther, 17, pp. 3-10, (2005)
[2]  
Nikolaou K., Flohr T., Knez A., Et al., Advances in cardiac CT imaging: 64-slice scanner, Int J Cardiovasc Imaging, 20, pp. 535-540, (2004)
[3]  
Awai K., Hiraishi K., Hori S., Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight, Radiology, 230, pp. 142-150, (2004)
[4]  
Sheiman R.G., Raptopoulos V., Caruso P., Vrachliotis T., Pearlman J., Comparison of tailored and empiric scan delays for CT angiography of the abdomen, AJR Am J Roentgenol, 167, pp. 725-729, (1996)
[5]  
Macari M., Israel G.M., Herman P., Lisi M., Tolia A.J., Adelman M., Et al., Infrarenal abdominal aortic aneurysms at multidetector row CT angiography: Intravascular enhancement without a timing acquisition, Radiology, 220, pp. 519-523, (2001)
[6]  
Awai K., Hatcho A., Nakayama Y., Kusunoki S., Liu D., Hatemura M., Et al., Simulation of aortic peak enhancement on MDCT using a contrast material flow phantom: Feasibility study, AJR Am J Roentgenol, 186, pp. 379-385, (2006)
[7]  
Bae K.T., Heiken J.P., Brink J.A., Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model, Radiology, 207, pp. 647-655, (1998)
[8]  
Bae K.T., Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model, Radiology, 227, pp. 809-816, (2003)
[9]  
Bae K.T., Heiken J.P., Brink J.A., Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model, Radiology, 207, pp. 657-662, (1998)
[10]  
Duddalwar V.A., Multislice CT angiography: A practical guide to CT angiography in vascular imaging and intervention, Br J Radiol, 77, SPEC 1, (2004)