Measurement of respiratory rate from the photoplethysmogram in chest clinic patients

被引:38
作者
Clifton D. [1 ]
Douglas G.J. [1 ]
Addison P.S. [2 ]
Watson J.N. [1 ]
机构
[1] CardioDigital Ltd, Elvingston Science Centre, Glasdmuir
[2] Department of Respiratory Medicine, Aberdeen Royal Infirmary
基金
英国惠康基金;
关键词
Photoplethysmogram; Respiratory rate; Wavelet transforms;
D O I
10.1007/s10877-006-9059-3
中图分类号
学科分类号
摘要
Objective: We studied the application of our algorithm for the robust extraction of respiratory information from the pulse oximeter signal acquired from a selection of patients attending the chest clinic. Methods: Photoplethysmograms were obtained from 16 individuals: 13 patients with various conditions in the respiratory ward and three healthy subjects. Wavelet transforms were generated from which respiratory information was extracted to obtain a measure of respiratory rate. This measured rate was compared with the respiratory rate determined by one of a variety of other means (a digital end tidal CO2 signal, the output from a non-invasive ventilation device, or a switch actuated by the patient or observer.) Results: Respiratory rates varied from 6.2 to 35.8 breaths per minute (bpm). The oximeter rate determined through our method matched the marker rate obtained for all patients to within 1 bpm. Conclusion: The technique allows the measurement of respiratory rate directly from the photoplethysmogram of a pulse oximeter, and leads the way for development of a simple non-invasive combined respiration and saturation monitor useful for patients with all forms of breathlessness. © Springer Science+Business Media, Inc. 2006.
引用
收藏
页码:55 / 61
页数:6
相关论文
共 19 条
[1]  
Folke M., Cernerud L., Ekstrom M., Hok B., Critical review of non-invasive respiratory monitoring in medical care, Med Biol Eng Comput, 41, pp. 377-383, (2003)
[2]  
Trafford J., Lafferty K., What does the photoplethysmograph measure?, Med Biol Eng Comput, 22, pp. 479-480, (1984)
[3]  
Moyle J.T., Pulse Oximetry, (1994)
[4]  
Addison P.S., Watson J.N., Secondary transform decoupling of shifted nonstationary signal modulation components: Application to photoplethysmography, Int J Wavelets Multiresol Inform Process, 2, pp. 43-57, (2004)
[5]  
Leonard P.A., Beattie T.F., Addison P.S., Watson J.N., Standard pulse oximeters can be used to monitor respiratory rate, Emerg Med J, 20, pp. 524-525, (2003)
[6]  
Leonard P.A., Grubb N.R., Addison P.S., Clifton D., Watson J.N., An algorithm for the detection of individual breaths from the pulse oximeter waveform, J Clin Monit Comput, 18, 5-6, pp. 309-312, (2005)
[7]  
Leonard P.A., Clifton D., Addison P.S., Watson J.N., Beattie T., An automated algorithm for the determination of respiration rate from the photoplethysmogram in children, Acta Paediatr, 95, pp. 1124-1128, (2006)
[8]  
Addison P.S., The Illustrated Wavelet Transform Handbook, (2002)
[9]  
Addison P.S., Wavelet analysis of the ECG: A review, Physiol Meas, 26, (2005)
[10]  
Aldroubi A., Unser M., Wavelets in Medicine and Biology, (1996)