Indications and technique of sentinel lymph node biopsy in breast cancer using 99m-technetium labeledtin colloids

被引:16
作者
Sato K. [1 ]
Uematsu M. [2 ]
Saito T. [5 ]
Ishikawa H. [1 ]
Yamasaki T. [1 ]
Tamaki K. [1 ]
Tamai S. [3 ]
Kusano S. [2 ]
Hiraide H. [4 ]
Mochizuki H. [1 ]
机构
[1] Department of Surgery i, National Defense Medical College, Tokorozawa 359-8513
[2] Departments of Radiology, National Defense Medical College
[3] Clinical Pathology, National Defense Medical College
[4] Research Institute, National Defense Medical College
[5] Department of Surgery, Omiya Red Cross Hospital
关键词
Breast cancer; Indication; Sentinel lymph node; Tin colloid;
D O I
10.1007/BF02967196
中图分类号
学科分类号
摘要
Background: The status of the sentinel lymph node (SLN) can reflect the status of other lymph nodes in breast cancer. The efficacy of dye injection and radiolabeled tin colloids for the accurate identification of the SLN was investigated. The indications for SLN biopsy for determing clinical nodal status were also investigated. Methods: A total of 108 patients with breast cancers less than 5 cm were enrolled. Ninety-six patients were clinically node negative and 12 were node positive. About 2 hours before surgery, 1 to 2.5 ml of 99m-technetium-labeled tin colloid was injected around the tumor. Just before the operation, dye was also injected into the tissue surrounding the tumor. Six clinically node negative patients were omitted from the dye-injection process. The SLN was identified as a lymph node with extremely high radioactivity using a gamma probe or a gamma counter. Complete axillary dissection was performed and the metastatic status investigated by hematoxylin and eosin staining. Results: In clinically node negative patients undergoing dye-injection, the SLN was identified in 89 of 90 patients (98.9%), and there was only one patient with lymph node metastasis outside the SLN. However, in clinically node positive patients undergoing dye-injection, the identification rate of the SLN was 66.7% (8 of 12 patients) and there was one patient with lymph node metastasis outside the SLN (12.5%). Without dye-injection, the SLN could be detected in 4 of 6 patients (66.7%). Conclusions: Successful identification of the SLN with tin colloid requires concomitant dye-injection and candidates for SLN biopsy should be restricted to clinically node negative cases.
引用
收藏
页码:95 / 98
页数:3
相关论文
共 30 条
[1]  
Cady B., Stone M.D., Wayne J., Hermann R.E., Mueller C.B., Foster Jr. R.S., Wanebo, Baker R.R., Gardner B., Spratt J.S., Montseur, New therapeutic possibilities in primary invasive breast cancer, Annals of Surgery, 218, 3, pp. 338-349, (1993)
[2]  
Carter C.L., Allen C., Henson D.E., Relation of tumor size, lymph node status, and survival in 24,740 breast cancer cases, Cancer, 63, 1, pp. 181-187, (1989)
[3]  
Dees E.C., Shulman L.N., Souba W.W., Et al., Does information from axillary dissection change treatment in clinically node-negative patients with breast cancer?
[4]  
An algorithm for assessment of impact of axillary dissection, Ann Surg, 226, pp. 279-286, (1997)
[5]  
Kissin M.W., Della Rovere Querci G., Easton D., Et al., Risk of lymphedema following the treatment of breast cancer, Br J Surg, 73, pp. 580-585, (1986)
[6]  
Morrow M., Management of the axillary nodes, Breast Cancer, 6, pp. 1-12, (1999)
[7]  
Assa J., The intercostobrachial nerve in radical mastectomy, J Surg Oncol, 6, pp. 123-126, (1974)
[8]  
Larson D., Weinstein M., Goldberg I., Edema of the arm as a function of the extent of axillary surgery in patients with stage I-II carcinoma of the breast treated with primary radiotherapy, International Journal of Radiation Oncology Biology Physics, 12, 9, pp. 1575-1582, (1986)
[9]  
Maunsell E., Brisson J., Deschenes L., Arm problems and psychological distress after surgery for breast cancer, Canadian Journal of Surgery, 36, 4, pp. 315-320, (1993)
[10]  
Hladiuk M., Huchcroft S., Temple W., Et al., Arm function after axillary dissection for breast cancer