Resect or not to resect: the role of posterior longitudinal ligament in lumbar total disc replacement

被引:2
作者
Balkan Cakir
Marcus Richter
Werner Schmoelz
René Schmidt
Heiko Reichel
Hans Joachim Wilke
机构
[1] University of Ulm,Department of Orthopaedic Surgery
[2] St. Josefs Hospital,Spine Unit
[3] Medical University of Innsbruck,Trauma Surgery and Sports Medicine
[4] University Medical Center Mannheim,Department of Orthopaedic and Trauma Surgery
[5] University of Ulm,Institute of Orthopaedic Research and Biomechanics
来源
European Spine Journal | 2012年 / 21卷
关键词
Lumbar disc replacement; Range of motion; Posterior longitudinal ligament; Biomechanics;
D O I
暂无
中图分类号
学科分类号
摘要
With regard to the literature, several factors are considered to have an impact on postoperative mobility after lumbar total disc replacement (TDR). As TDR results in a distraction of the ligamentous structures, theoretically the postoperatively disc height and ligamentous integrity have also an influence on biomechanics of a treated segment. The purpose of the study was to evaluate the influence of posterior longitudinal ligament (PLL) resection and segmental distraction on range of motion (ROM). Six human, lumbar spines (L2–L3) were tested with pure moments of ±7.5 Nm in a spine loading apparatus. The ROM was determined in all three motion planes. Testing sequences included: (1) intact state, (2) 10 mm prosthesis (PLL intact), (3) 10 mm prosthesis (PLL resected), (4) 12 mm prosthesis (PLL resected). The prosthesis used was a prototype with a constrained design using the ball-and-socket principle. The implantation of the 10 mm prosthesis already increased the disc height significantly (intact: 9.9 mm; 10 mm prosthesis: 10.6 mm; 12 mm prosthesis: 12.7 mm). Compared to the intact status, the implantation of the 10 mm prosthesis resulted in an increase of ROM for flexion/extension (8.6° vs 10.8°; P = 0.245) and axial rotation (2.9° vs 4.5°; P = 0.028), whereas lateral bending decreased (9.0° vs 7.6°; P = 0.445). The resection of the PLL for the 10 mm prosthesis resulted in an increase of ROM in all motion planes compared to the 10 mm prosthesis with intact PLL (flexion/extension: 11.4°, P = 0.046; axial rotation: 5.1°, P = 0.046; lateral bending: 8.6°, P = 0.028). The subsequent implantation of a 12 mm prosthesis, with resected PLL, resulted in a significant decrease of ROM in all motion planes compared to the 10 mm prosthesis with intact PLL (flexion/extension: 8.4°, P = 0.028; axial rotation: 3.3°, P = 0.028; lateral bending: 5.1°, P = 0.028). Compared to the intact status, the 12 mm prosthesis with resected PLL only decreased lateral bending significantly while the 10 mm prosthesis with intact PLL increased axial rotation significantly. The resection of the PLL during TDR results in a significant increase of ROM in all three principle motion planes. But it still remains unclear if this increase which is in median not more than 1° may alter the clinical results. Moreover, the destabilizing effect of PLL resection can be reversed using a higher implant. The prosthesis height seems more crucial than PLL preservation to maintain the primary stability after TDR.
引用
收藏
页码:592 / 598
页数:6
相关论文
共 89 条
[1]
Bertagnoli R(2002)Indications for full prosthetic disc arthroplasty: a correlation of clinical outcome against a variety of indications Eur Spine J 11 131-136
[2]
Kumar S(2004)Sagittales Alignement und segmentale Beweglichkeit nach endoprothetischer Versorgung lumbaler Bewegungssegmente Z Orthop Ihre Grenzgeb 142 159-165
[3]
Cakir B(1990)Correlation between disc height narrowing and low-back pain Spine 15 1366-1369
[4]
Schmidt R(1993)Lumbar disc prosthesis. Surgical technique, indications and clinical results in 22 patients with a minimum of 12 months follow-up Eur Spine J 1 254-259
[5]
Huch K(2003)ProDisc artificial total lumbar disc replacement: introduction and early results from the united states clinical trial Spine 28 167-175
[6]
Puhl W(2002)Der Bandscheibenersatz mit der SB Charite-Bandscheibenendoprothese-Erfahrungen, Frühergebnisse und Feststellungen nach 35 prospektiv durchgeführten Operationen Z Orthop Ihre Grenzgeb 140 485-491
[7]
Richter M(2005)Correlation between range of motion and outcome after lumbar total disc replacement: 8.6-year follow-up Spine 30 1407-1411
[8]
Dabbs VM(2006)Effect of the increase in the height of lumbar disc space on facet joint articulation area in sagittal plane Spine 31 E198-E202
[9]
Dabbs LG(2002)Non-fusion technology in degenerative lumbar spinal disorders: facts, questions, challenges Eur Spine J 11 85-91
[10]
David T(1996)Magnetic resonance imaging and biological changes in injured intervertebral discs under normal and increased mechanical demands Spine 21 1945-1951