Multi-Unit and Multi-Path system of the neural network can explain the steep dose-response of MAC

被引:4
作者
Kaminoh Y. [1 ]
Kamaya H. [2 ]
Tashiro C. [1 ]
Ueda I. [2 ]
机构
[1] Department of Anesthesiology, Hyogo College of Medicine, Nishinomiya 663-8501
[2] Department of Anesthesiology, Univ. of Utah School of Medicine, Salt Lake City, UT
关键词
Anesthesia mechanism; Dose-response curve; MAC;
D O I
10.1007/s00540-003-0224-2
中图分类号
学科分类号
摘要
Purpose. The slope of the dose-response curves of inhalation anesthetics is steep around the minimum alveolar concentration of inhalation anesthetics (MAC) value. Contrastingly, the anesthetic dose-response curves of ion channels and enzymes are gradual. This discrepancy in the steepness may be a key to solve the mechanisms of anesthesia. To explain the steepness we propose a mathematical model of the neural network related to MAC. Methods. We assumed that, in order to show movement in response to a noxious stimulus, a signal needed to be transmitted from A to B. There are m conduction pathways (Multi-Path) in the nerve network between A and B, and there are n conduction units (Multi-Unit) in each conduction pathway. Anesthetics bind to each conduction unit and block signal transmission. Anesthetics prevent movement in response to a stimulus, when at least one conduction unit among all conduction pathways has been blocked. We derived the equation for the probability of the signal being blocked by anesthetics. Results. The steep dose-response curve of in vivo anesthesia requires a very large number of conduction units (n > 100) and conduction pathways (m > 106). The EC50 for each conduction unit was at least 3.8-fold larger than the apparent EC50 for the whole system under the experimental condition of simulation. Conclusions. We constructed a model for the neural networks that relates to MAC as a Multi-Unit and Multi-Path system (MUMPS). To obtain highly cooperative dose-response curves comparable to those of in vivo anesthesia, at least 106 conduction pathways and more than 100 conduction units are required for each pathway. In these systems, the apparent anesthetic potency on the whole system (MAC) is much stronger than the anesthetic action on each unit. Because of this discrepancy, it is important to set anesthetic concentrations appropriately for experiments with in vitro systems. © JSA 2004.
引用
收藏
页码:94 / 99
页数:5
相关论文
共 11 条
[1]  
Sonner J.M., Antognini J.F., Dutton R.C., Flood P., Gray A.T., Harris R.A., Homanics G.E., Kendig J., Orser B., Raines D.E., Trudell J., Vissel B., Eger E.I., Inhaled anesthetics and immobility: Mechanisms, mysteries, and minimum alveolar anesthetic concentration, Anesth. Analg., 97, pp. 718-740, (2003)
[2]  
Urban B.W., Bleckwenn M., Concepts and correlations relevant to general anaesthesia, Br. J. Anaesthesia, 89, pp. 2-16, (2002)
[3]  
Waud D.R., On biological assays involving quantal responses, J. Pharmacol. Exp. Ther., 183, pp. 577-607, (1972)
[4]  
Yamakura T., Batrtaccini D., Trudell J.R., Harris R.A., Anesthetics and ion channels: Molecular model and sites of action, Annu. Rev. Pharmacol. Toxicol., 41, pp. 23-51, (2000)
[5]  
Kumamoto E., Murata Y., Enhancement by lanthanide of general anesthetic-induced GABAA-receptor current in rat septal cholinergic neurons in culture, J. Neurophysiol., 75, pp. 2294-2299, (1996)
[6]  
Jenkins A., Franks N.P., Lieb W.R., Effects of temperature and volatile anesthetics on GABA(A) receptors, Anesthesiology, 90, pp. 484-491, (1999)
[7]  
Katoh T., Ikeda K., Minimum alveolar concentration of sevoflurane in children, Br. J. Anaesthesia, 68, pp. 139-141, (1992)
[8]  
Eckenhoff R.G., Johansson J.S., On the relevance of "clinically relevant concentrations" of inhaled anesthetics in in vitro experiments, Anesthesiology, 91, pp. 856-860, (1999)
[9]  
Ueda I., The steep dose-response curves of anesthesia, Anesthesiology, 96, (2002)
[10]  
Eger E.I., Fisher D.M., Dilger J.P., Sonner J.M., Evers A., Franks N.P., Harris R.D., Kendig J.J., Lieb W.R., Yamakura T., Relevant concentrations of inhaled anesthetics for in vitro studies of anesthetic mechanisms, Anesthesiology, 94, pp. 915-921, (2001)