The pronator quadratus muscle after plating of distal radius fractures: Is the muscle still working?

被引:39
作者
Armangil M. [1 ,2 ]
Bezirgan U. [3 ]
Başarir K. [4 ]
Bilen G. [5 ]
Demirtaş M. [1 ]
Bilgin S.S. [1 ]
机构
[1] Department of Hand Surgery, Ankara University, School of Medicine, Ankara
[2] Ortopedi Ve Travmatoloji ABD Sekreterliǧi, Fakültesi Ibni Sina Hastanesi, Ankara Universitesi Tip, Sihhiye, Samanpazari, Ankara
[3] Diyarbakir State Hospital, Ankara
[4] Orthopedics and Traumatology Department, Ankara University School of Medicine, Ankara
[5] Sports Medicine Department, Ankara University School of Medicine, Ankara
关键词
Anterior approach; Distal radius fracture; Muscle function; ORIF; Plate osteosynthesis; Pronator quadratus; Surgery outcome; Volar approach;
D O I
10.1007/s00590-013-1193-2
中图分类号
学科分类号
摘要
The purpose of this study is to define the function of the pronator quadratus muscle after plating of a distal radius fracture using anterior (volar) approach. Fourteen cases with volar plating after for a distal radius fracture were included in the study. Sixteen healthy volunteers were selected to determine the effect of dominant arm on pronation torque of the forearm for the control group. Biodex System 4 PRO (Biodex Medical Systems Inc., New York) torque meter was used for pronation torque measurement. In healthy volunteer group, there was no statistically significant difference in mean pronation torque values between the dominant arm and nondominant arms. The mean loss of pronator strength was 18.5 % and the mean loss of pronator durability was 12.9 % indicating a pronator insufficiency in the cases operated by a volar approach compared to uninjured forearm. Two patients among the operated group, who had further strengthening exercises beyond their own rehabilitation regimes, had improved pronator torque compared to uninjured forearm. In conclusion, the results of this study indicate that following volar plating of distal radius fractures, there is a significant loss in pronator strength of the forearm. As the two of the patients had improved pronator strength of their operated forearm, further rehabilitation regimes should be considered to prevent pronator weakness following volar plating for distal radius fractures. © 2013 Springer-Verlag.
引用
收藏
页码:335 / 339
页数:4
相关论文
共 18 条
[1]
Taras J.S., Ladd A.L., Kalainov D.M., Ruch D.S., Ring D.C., New concepts in the treatment of distal radius fractures, Instr Course Lect, 59, pp. 313-332, (2010)
[2]
Gordon K.D., Dunning C.E., Johnson J.A., King G.J.W., Influence of the Pronator Quadratus and Supinator Muscle Load on DRUJ Stability, Journal of Hand Surgery, 28, 6, pp. 943-950, (2003)
[3]
Hakimi M., Jungbluth P., Windolf J., Wild M., Functional results and complications following locking palmar plating on the distal radius: A retrospective study, J Hand Surg Eur, 35, pp. 283-288, (2010)
[4]
Protopsaltis T.S., Ruch D.S., Volar Approach to Distal Radius Fractures, Journal of Hand Surgery, 33, 6, pp. 958-965, (2008)
[5]
Kleinman W.B., Stability of the distal radioulna joint: Biomechanics, pathophysiology, physical diagnosis, and restoration of function what we have learned in 25 years, J Hand Surg Am, 32, pp. 1086-1106, (2007)
[6]
Orbay J.L., Badia A., Indriago I.R., Infante A., Khouri R.K., Gonzalez E., Fernandez D.L., The extended flexor carpi radialis approach: A new perspective for the distal radius fracture, Techniques in Hand and Upper Extremity Surgery, 5, 4, pp. 204-211, (2001)
[7]
Lichtman D.M., Bindra R.R., Boyer M.I., Et al., American Academy of Orthopaedic Surgeons clinical practice guideline on: The treatment of distal radius fractures, J Bone Joint Surg Am, 20, pp. 775-778, (2011)
[8]
Ilyas A.M., Jupiter J.B., Distal radius fractures - classification of treatment and indications for surgery, Hand Clin, 26, pp. 37-42, (2010)
[9]
Souer J.S., Ring D., Jupiter J., Matschke S., Audige L., Marent-Huber M., Comparison of intraarticular simple compression and extra-articular distal radial fractures, J Bone Joint Surg Am, 16, pp. 2093-2099, (2011)
[10]