The effects of radiotherapy treatment uncertainties on the delivered dose distribution and tumour control probability

被引:9
作者
Booth J.T. [1 ,2 ]
Zavgorodni S.F. [1 ,2 ]
机构
[1] Department of Physics and Mathematical Physics, Adelaide University
[2] Department of Medical Physics, Royal Adelaide Hospital
来源
Australasian Physics & Engineering Sciences in Medicine | 2001年 / 24卷 / 2期
关键词
Dose distribution; Treatment uncertainty; Tumour control probability;
D O I
10.1007/BF03178349
中图分类号
学科分类号
摘要
Uncertainty in the precise quantity of radiation dose delivered to tumours in external beam radiotherapy is present due to many factors, and can result in either spatially uniform (Gaussian) or spatially non-uniform dose errors. These dose errors are incorporated into the calculation of tumour control probability (TCP) and produce a distribution of possible TCP values over a population. We also study the effect of inter-patient cell sensitivity heterogeneity on the population distribution of patient TCPs. This study aims to investigate the relative importance of these three uncertainties (spatially uniform dose uncertainty, spatially non-uniform dose uncertainty, and inter-patient cell sensitivity heterogeneity) on the delivered dose and TCP distribution following a typical course of fractionated external beam radiotherapy. The dose distributions used for patient treatments are modelled in one dimension. Geometric positioning uncertainties during and before treatment are considered as shifts of a pre-calculated dose distribution. Following the simulation of a population of patients, distributions of dose across the patient population are used to calculate mean treatment dose, standard deviation in mean treatment dose, mean TCP, standard deviation in TCP, and TCP mode. These parameters are calculated with each of the three uncertainties included separately. The calculations show that the dose errors in the tumour volume are dominated by the spatially uniform component of dose uncertainty. This could be related to machine specific parameters, such as linear accelerator calibration. TCP calculation is affected dramatically by inter-patient variation in the cell sensitivity and to a lesser extent by the spatially uniform dose errors. The positioning errors with the 1.5 cm margins used cause dose uncertainty outside the tumour volume and have a small effect on mean treatment dose (in the tumour volume) and tumour control.
引用
收藏
页码:71 / 78
页数:7
相关论文
共 21 条
[1]  
Kron T., Bazley S., Roff M., Hamilton C., Denham J., A level 3 dosimetric intercomparison for Australasia: A pilot study, Proceedings of Engineering and the Physical Sciences in Medicine, Hobart, (1998)
[2]  
ICRU Report 50 Prescribing, Recording and Reporting Photon Beam Therapy, (1993)
[3]  
ICRU Report 62 Prescribing, Recording and Reporting Photon Beam Therapy (Supplement to ICRU Report 50), (1999)
[4]  
Leong J., Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation, Phys. Med. Biol., 32, 3, pp. 327-334, (1987)
[5]  
Urie M.M., Goitein M., Doppke K., Kutcher J.G., LoSasso T., Mohan R., Munzenrider J.E., Sontag M., Wong J.W., The role of uncertainty analysis in treatment planning, Int. J. Radiat. Oncol. Biol. Phys., 21, pp. 91-107, (1991)
[6]  
Keall P.J., Beckham W.A., Booth J.T., Zavgorodni S.F., Opelaar M., A method to predict the effect or organ motion and set-up variations on treatment plans, Australas. Phys. Eng. Sci. Med., 22, pp. 48-52, (1999)
[7]  
Killoran J.H., Kooy H.M., Gladstone D.J., Welte F.J., Beard C.J., A numerical simulation of organ motion and daily setup uncertainties: Implications for radiation therapy, Int. J. Radiat. Oncol. Biol. Phys., 37, 1, pp. 213-221, (1997)
[8]  
Boyer A.L., Schultheiss T., Effects of dosimetric and clinical uncertainty on complication-free local tumor control, Radiother. Oncol., 11, pp. 65-71, (1988)
[9]  
Michalski J.M., Wong J.W., Gerber R.L., Yan D., Cheng A., Graham M.V., Renna M.A., Sawyer P.J., Perez C.A., The use of on-line image verification to estimate the variation in radiation therapy dose delivery, Int. J. Radiat. Oncol. Biol. Phys., 27, pp. 701-716, (1993)
[10]  
Stroom J.C., Koper P.C.M., Korevaaar G.A., Van Os M., Janssen M., De Boer H.C.J., Levendag P.C., Heijmen B.J.M., Internal organ motion in prostate cancer patients treated in prone and supine treatment position, Radiother. Oncol., 51, pp. 237-248, (1999)