"CADEAT": considerations on the use of CAD (computer-aided diagnosis) in mammography

被引:2
作者
Chersevani, R. [2 ]
Ciatto, S. [1 ]
Del Favero, C. [3 ]
Frigerio, A. [4 ]
Giordano, L. [5 ]
Giuseppetti, G. [6 ]
Naldoni, C. [7 ]
Panizza, P. [8 ]
Petrella, M. [9 ]
Saguatti, G. [10 ]
机构
[1] Ist Sci Prevenz Oncol, ISPO, I-50131 Florence, Italy
[2] Soc Italiana Radiol Med, Sez Studio Senol, Milan, Italy
[3] Fdn Don Carlo Gnocchi IRCS, Milan, Italy
[4] AOU S Giovanni Battista, Ctr Riferimento Reg Screening Mammograf, Turin, Italy
[5] AOU S Giovanni Battista, CPO Piemonte, Unita Epidemiol, Turin, Italy
[6] Univ Politecn Marche, Fac Med, Ancona, Italy
[7] Ctr Riferimento & Coordinamento Screening Oncol, Bologna, Italy
[8] Univ Milan, Osped San Raffaele, Dipartimento Radiol, I-20127 Milan, Italy
[9] AUSL 2 Umbria, Programma Aziendale Screening, Perugia, Italy
[10] AUSL, Ctr Senol, Presidio Osped Maggiore, Bologna, Italy
来源
RADIOLOGIA MEDICA | 2010年 / 115卷 / 04期
关键词
Breast cancer; Mammography; Diagnosis; Computer aided diagnosis; BREAST-CANCER DETECTION; SCREENING MAMMOGRAMS; RECALL RATES; STANDARD;
D O I
10.1007/s11547-010-0505-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computer-aided diagnosis (CAD) has been extensively reported to increase sensitivity by about 10% when added to a single reading while increasing recall rate by 12%, and its current use can be safely recommended in clinical practice. CAD has been suggested as a possible alternative to conventional double reading in screening. Uncontrolled comparison is consistent and suggests that CAD is comparable to double reading in incremental cancer detection rate (CAD +10.6%, double reading +9.1%) and possibly better in recall rate (CAD +12.5%, double reading +28.8%). However, controlled studies comparing single reading + CAD to conventional double reading are not consistent and on average suggest a lower cancer detection rate (-5.1%) and a lower recall rate (-9.8%) for CAD. Scientific evidence is not sufficient for a safe recommendation of single reading + CAD as a current alternative to conventional double reading.
引用
收藏
页码:563 / 570
页数:8
相关论文
共 28 条
[1]   THE EFFICACY OF DOUBLE READING MAMMOGRAMS IN BREAST SCREENING [J].
ANDERSON, EDC ;
MUIR, BB ;
WALSH, JS ;
KIRKPATRICK, AE .
CLINICAL RADIOLOGY, 1994, 49 (04) :248-251
[2]   CAD systems for mammography: A real opportunity? A review of the literature [J].
Bazzocchi M. ;
Mazzarella F. ;
Del Frate C. ;
Girometti F. ;
Zuiani C. .
La radiologia medica, 2007, 112 (3) :329-353
[3]  
Bazzocchi M, 2001, Radiol Med, V101, P334
[4]   Computer-aided detection with screening mammography in a university hospital setting [J].
Birdwell, RL ;
Bandodkar, P ;
Ikeda, DM .
RADIOLOGY, 2005, 236 (02) :451-457
[5]   Second reading of screening mammograms increases cancer detection and recall rates. Results in the Florence screening programme [J].
Ciatto, S ;
Ambrogetti, D ;
Bonardi, R ;
Catarzi, S ;
Risso, G ;
Del Turco, MR ;
Mantellini, P .
JOURNAL OF MEDICAL SCREENING, 2005, 12 (02) :103-106
[6]   Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review [J].
Ciatto, S ;
Del Turco, MR ;
Burke, P ;
Visioli, C ;
Paci, E ;
Zappa, M .
BRITISH JOURNAL OF CANCER, 2003, 89 (09) :1645-1649
[7]   Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammography [J].
Ciatto, S ;
Del Turco, MR ;
Risso, G ;
Catarzi, S ;
Bonardi, R ;
Viterbo, V ;
Gnutti, P ;
Guglielmoni, B ;
Pinelli, L ;
Pandiscia, A ;
Navarra, F ;
Lauria, A ;
Palmiero, R ;
Indovina, PL .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (02) :135-138
[8]   Computer-assisted diagnosis (CAD) in mammography: comparison of diagnostic accuracy of a new algorithm (CyclopusA®, Medicad) with two commercial systems [J].
Ciatto, S. ;
Cascio, D. ;
Fauci, F. ;
Magro, R. ;
Raso, G. ;
Ienzi, R. ;
Martinelli, F. ;
Simone, M. Vasile .
RADIOLOGIA MEDICA, 2009, 114 (04) :626-635
[9]  
Ciatto Stefano, 2004, Radiol Med, V107, P480
[10]  
Ciatto Stefano, 2003, Radiol Med, V106, P59