Intraperitoneal (IP) ventral hernia repair has been proposed with the advantages of reducing dissection, operative time, and postoperative pain. The IP position of the mesh is suspected of increasing the risk of visceral adhesion and inducing complications. To overcome these drawbacks, a mesh protected on one side by a hydrophilic resorbable film (Parietex Composite) has been validated [1]. Using a previously described ultrasound procedure [2], the purpose of this study was to compare the rate of visceral adhesion after intraperitoneal placement of a polyester mesh versus this protected mesh. Fifty-one patients who received a Parietex Composite mesh were prospectively compared to a retrospective series of 22 consecutive asymptomatic patients who received a Mersilene mesh. To objectively assess visceral adhesion toward the abdominal wall, an ultrasound (US) specific examination was firstly validated and secondly used to evaluate the adhesion incidence in both groups. Both groups were equivalent in terms of inclusion criteria and body mass index (BMI). Pre-operative US versus perioperative macroscopical findings determined the following parameters: sensitivity 83%, accuracy 78%, negative predictive value 81%. Using this procedure, 77% of the patients exhibited visceral adhesion to the mesh in the Mersilene group, against 18% in the Parietex Composite group (P < 0.001, chi-square). US examination represents a suitable tool to evaluate postoperative adhesions to the abdominal wall. Using this procedure, a significant reduction of visceral adhesion in the Parietex Composite group was shown.
引用
收藏
页码:85 / 88
页数:3
相关论文
共 19 条
[1]  
Balique J.G., Alexandre J.H., Arnaud J.P., Benchetrit S., Bouillot J.L., Fagniez P.L., Flament J.B., Gouillat C., Jarsaillon P., Lepere M., Magne E., Mantion G., Intraperitoneal treatment of incisional and umbilical hernias: Intermediate results of a multicenter prospective clinical trial using an innovative composite mesh, Hernia, 4, SUPPL., (2000)
[2]  
Sigel B., Golub R.M., Loiacono L.A., Parsons R.E., Kodama I., Machi J., Justin J., Sachdeva A.K., Zaren H.A., Technique of ultrasonic detection and mapping of abdominal wall adhesions, Surg Endosc, 5, pp. 161-165, (1991)
[3]  
Bourgeon R., Borelli J.P., Lanfranchi J.P., Utilisation des prothèses de mersilène dans de traitement des éventrations postopératoires, Ann Chir, 26, pp. 541-545, (1972)
[4]  
Arnaud J.P., Eloy R., Adloff M., Grenier J.F., Critical evaluation of prosthetic materials in repair of abdominal wall hernia: New criteria of tolerance and resistance, Ann Surg, 133, pp. 338-345, (1977)
[5]  
Arnaud J.P., Cervi C., Tuech J.J., Cattan F., Surgical treatment of postoperative incisional hernias by intra-peritoneal insertion of a Dacron mesh. A report on 220 cases, Hernia, 1, pp. 97-99, (1997)
[6]  
Welti H., Eudel F., Un procédé de cure radicale des éventrations postopératoires par auto-étalement des muscles grands droits après incision du feuillet antérieur de leur gaine, Mem Acad Chir, 12, pp. 791-798, (1941)
[7]  
Kodama I., Loiacono L.A., Sigel B., Machi J., Golub R.M., Parsons R.E., Zaren H.A., Sachdeva A.K., Ultrasonic detection of visceral slide as an indicator of abdominal wall adhesions, J Clin Ultrasound, 20, pp. 275-380, (1992)
[8]  
Deguzman L.J., Nyphus L.M., Yared G., Colocutaneous fistula formation following polypropylene mesh placement for repair of a ventral hernia: Diagnosis by colonoscopy, Endoscopy, 27, pp. 257-261, (1995)
[9]  
Marchal F., Brunaud L., Sebbag H., Bresler L., Tortuyaux J.M., Boissel P., Treatment of incisional hernias by placement of an intraperitoneal prothesis: A series of 128 patients, Hernia, 31, pp. 141-147, (1999)
[10]  
Goldberg J.M., Toledu A.A., Mitchel D.R., An evaluation of the gore-tex surgical membrane for the prevention of post-operative peritoneal adhesions, Surg Gynecol Obstet, 70, pp. 846-848, (1987)