Effect of the flow field of mechanical bileaflet mitral prostheses on valve closing

被引:11
作者
Akutsu T. [1 ]
Imai R. [1 ]
Deguchi Y. [1 ]
机构
[1] Department of Mechanical Engineering, College of Engineering, Kanto Gakuin University, Kanazawa-ku, Yokohama 236-8501
关键词
Biofluid mechanics; Flow visualization; Medical equipment; PIV; Prosthetic heart valve;
D O I
10.1007/s10047-005-0297-9
中图分类号
学科分类号
摘要
Antianatomically installed Jyros (JR) and ATS valves were compared with the St. Jude Medical (SJM) valve in the mitral position to study the effects of valve design on the downstream flow field and associated closing sounds using a particle image velocimetry (PIV) method utilizing a high-speed video flow visualization technique to map the velocity field and sound measurement to confirm claims by the manufacturer. Based on the experimental data, the following general conclusions can be made: in the velocity field directly below the mitral valve, where distinct characteristic differences in valve design can be seen, symmetrical twin circulations were observed because of the divergent nature of the flow generated by the two inclined half-disks installed in the antianatomical orientation; the SJM valve, which produced central downward circulation, is contrasted to the two other valves, which produced peripheral downward circulation. These differences may play an important role in the closing behavior of the valve leaflets, thus affecting the generation of the valve closing sound. © The Japanese Society for Artificial Organs 2005.
引用
收藏
页码:161 / 170
页数:9
相关论文
共 13 条
[1]  
Hufnagel C.A., Harvey W.P., Rabil P.J., McDermott T.F., Surgical correction of aortic insufficiency, Surgery, 35, pp. 673-683, (1954)
[2]  
Starr A., Edwards M.L., McCord C.W., Griswold H.E., Aortic replacement clinical experience with a semirigid ball-valve prosthesis, Circulation, 27, pp. 779-783, (1963)
[3]  
Aoyagi N., Tanaka I., Nishi Y., Yamashita M., Oryouji A., Hara T., Kosuga K., Ooishi K., Long-term result of MRV by SJM valve, J Jpn Thorac Cardiovasc Surg, 39, pp. 1126-1130, (1991)
[4]  
Baudet E.M., Oca C.C., Roques X.F., Laborde M.N., Hafez A.S., Collot M.A., Ghidoni I.M., A 51/2-year experience with the St. Jude Medical cardiac valve prosthesis. Early and late results of 737 valve replacements in 671 patients, J Thorac Cardiovasc Surg, 90, pp. 137-144, (1985)
[5]  
Duveau D., Michaud J.L., Despins P., Patra P., Train M., Dupon H., Rozo L., Carlier R., De Bakey M.E., Mitral valve replacement with the St. Jude Medical prosthesis: 242 cases with clinical results and an evaluation of prosthesis positioning, Advances in Cardiac Valves, Clinical Perspectives (Proceedings of the Third International Symposium on the St. Jude Valve, November 1982, Scottsdale, Arizona), pp. 183-190, (1983)
[6]  
Akutsu T., Higuchi D., Effect of mechanical prosthetic heart valve orientation on the flow field inside the simulated ventricle: Comparison between St. Jude Medical valve and Medtronic-Hall valve, J Artif Organs, 2, pp. 39-45, (1999)
[7]  
Akutsu T., Higuchi D., Effect of the mechanical prosthetic mono- and bileaflet heart valve orientation on the flow field inside the simulated ventricle, J Artif Organs, 3, pp. 126-135, (2000)
[8]  
Akutsu T., Higuchi D., Flow analysis of the bileaflet mechanical prosthetic heart valve using laser Doppler anemometry: Effect of the valve design and installed orientation on the flow inside the simulated left ventricle, J Artif Organs, 4, pp. 113-125, (2001)
[9]  
Feng Z., Umezu M., Fujimoto T., Tsukahara T., Nurishi M., Kawaguchi D., Masuda S., Analysis of ATS leaflet behavior by in vitro experiment, J Artif Organs, 2, pp. 46-52, (1999)
[10]  
Modi V.J., Bishop W.F., Akutsu T., Unsteady fluid dynamics of three contemporary heart valves using a two-component LDA system, Artif Organs, 14, pp. 103-107, (1991)