Long-term experience with the Sorin Bicarbon and Edwards Mira mechanical valve prostheses in the mitral position

被引:5
作者
Fukui T. [1 ]
Shibata T. [2 ]
Sasaki Y. [1 ]
Hirai H. [1 ]
Motoki M. [1 ]
Takahashi Y. [1 ]
Suehiro S. [1 ]
机构
[1] Department of Cardiovascular Surgery, Osaka City University, Graduate School of Medicine, Abeno-ku, Osaka 545-8585
[2] Department of Cardiovascular Surgery, Kansai Rosai Hospital, Hyogo
关键词
Heart valve disease; Mechanical valve; Mitral valve; Mitral valve replacement;
D O I
10.1007/s11748-006-0081-7
中图分类号
学科分类号
摘要
Objective. Sorin Bicarbon (SB) and Edwards Mira (EM) valves have an identical mechanical design but different sewing cuffs. The purpose of this retrospective study was to analyze the long-term clinical and echocardiographic outcomes after mitral valve replacement with these two valves in a combined population of patients. Methods. We retrospectively reviewed records of 73 patients who underwent mitral valve replacement using SB (n = 19) or EM (n = 54) valves. Preoperatively, 49 patients (68.1%) were in New York Heart Association (NYHA) functional class III or IV. Concomitant procedures were performed in 52 patients (71.2%). Early and late postoperative echocardiography was performed in 69 and 57 patients, respectively. Results. Operative mortality was 4.1%, and early morbidity was 9.6%. Overall patient survival at 9 years was 85.1% ± 4.8%. Actuarial freedom from valve-related death was 95.4% ± 2.6% at 9 years. As shown by Doppler echocardiography, the early and late mean transprosthetic pressure gradients were 3.4 ± 1.4mmHg and 3.8 ± 2.1mmHg, respectively. At the end of follow-up, 98.4% of survivors were in NYHA class I or II. Conclusion. The Sorin Bicarbon and Edwards Mira mechanical valves in the mitral position provide satisfactory long-term clinical and echocardiographic performance. © 2007 The Japanese Association for Thoracic Surgery.
引用
收藏
页码:91 / 97
页数:6
相关论文
共 25 条
[1]  
Grossi E.A., Galloway A.C., Miller J.S., Ribakove G.H., Culliford A.T., Esposito R., Et al., Valve repair versus replacement for mitral insufficiency: When is a mechanical valve still indicated?, J Thorac Cardiovasc Surg, 115, pp. 389-94, (1998)
[2]  
Zellner J.L., Kratz J.M., Crumbley III A.J., Stroud M.R., Bradley S.M., Sade R.M., Et al., Long-term experience with the St. Jude Medical valve prosthesis, Ann Thorac Surg, 68, pp. 1210-8, (1999)
[3]  
Remadi J.P., Baron O., Roussel C., Bizouarn P., Habasch A., Despins P., Et al., Isolated mitral valve replacement with St Jude medical prosthesis: Long-term results: A follow-up of 19 years, Circulation, 103, pp. 1542-5, (2001)
[4]  
Ikonomidis J.S., Kratz J.M., Crumbley III A.J., Stroud M.R., Bradley S.M., Sade R.M., Et al., Twenty-year experience with the St Jude Medical mechanical valve prosthesis, J Thorac Cardiovasc Surg, 126, pp. 2022-31, (2003)
[5]  
Emery R.W., Krogh C.C., Arom K.V., Emery A.M., Benyo-Albrecht K., Joyce L.D., Et al., The St. Jude Medical cardiac valve prosthesis: A 25-year experience with single valve replacement, Ann Thorac Surg, 79, pp. 776-82, (2005)
[6]  
Vallana F., Rinaldi S., Galletti P.M., Nguyen A., Piwnica A., Pivot design in bileaflet valves, ASAIO J, 38, pp. 600-6, (1992)
[7]  
Vitale N., Cappabianca G., Visicchio G., Fondacone C., Paradiso V., Mannatrizio G., Et al., Midterm evaluation of the Sorin Bicarbon heart valve prosthesis: Single-center experience, Ann Thorac Surg, 77, pp. 527-31, (2004)
[8]  
Whitaker D.C., James S.E., Walesby R.K., A single-center experience of the Sorin Bicarbon heart valve prosthesis: Long-term clinical, hematological and hemodynamic results, J Heart Valve Dis, 13, pp. 97-102, (2004)
[9]  
Remadi J.P., Marticho P., Nzomvuama A., Degandt A., Preliminary results of 130 aortic valve replacements with a new mechanical bileaflet prosthesis: The Edwards MIRA valve, Interact Cardiovasc Thorac Surg, 2, pp. 80-3, (2003)
[10]  
Vitale N., De Feo M., Renzulli A., Gregorio R., Cappabianca G., Onorati F., Et al., Ten-year outcome with the sorin bicarbon and Baxter Mira bileaflet prostheses in the aortic position, J Heart Valve Dis, 13, pp. 632-7, (2004)