A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors: Comparison with the continuous thermodilution method early cardiovascular monitors

被引:46
作者
Ishihara H. [1 ]
Okawa H. [1 ]
Tanabe K. [1 ]
Tsubo T. [1 ]
Sugo Y. [2 ]
Akiyama T. [2 ]
Takeda S. [2 ]
机构
[1] Department of Anesthesiology, University of Hirosaki, School of Medicine, Hirosaki-Shi 036-8562
[2] Reserch and Development Laboratory, Nihon Kohden Corporation, Tokyo
关键词
Cardiac output; Cardiac surgery; Measurement technique; Postoperative period; Pulse contour analysis; Thermodilution;
D O I
10.1007/s10877-005-2452-5
中图分类号
学科分类号
摘要
Objective. Three of the us developed a new non-invasive continuous cardiac output (CCO) measurement method utilizing routine clinical monitors based on the pulse-contour analysis combined with pulse wave transit time (PWTT). Using pulmonary artery catheter (CCOpa), we compared this estimated CCO (esCO) with the thermodilution CCO early after cardiac surgery, and tested whether the esCO method has potential of being an alternative measure of CCO. Methods. Thirty-six patients without continued arrhythmias were studied. esCO was computed using electrocardiogram (ECG) monitor, arterial pressure monitor and pulse-oximetry system. Both sets of data (esCO and CCOpa), by averaging the results of the preceding 10 min, were compared at 30-min intervals throughout the 15.8± 3.3 h (S.D.) of study. Bland - Altman plots and correlation analysis were used for statistical comparison. Results. A total of 981 paired sets of data (89.9%) among 1093 measurements were compared in the absence of displacement of either pulse-oximetry or ECG probes and/or inaccurate detection of R wave. The difference between esCO and CCOpa results was -0.06 ± 0.82 L/min (S.D.), and there was a linear correlation between them (r = 0.80, p < 0.0001). The difference between them was 0.00± 0.48 L/min at the first 1 h, which remained unchanged throughout 20 h after the start of measurement. Conclusions. The results demonstrate that esCO has a close correlation with the CCOpa, even though the two methods are not interchangeable. The results suggest that esCO metho d has potential of being an alternative non-invasive cardiac output trend, unless there are apparent arrhythmias. © Springer Science + Business Media, Inc. 2005.
引用
收藏
页码:313 / 320
页数:7
相关论文
共 15 条
[1]  
Kouchoukos N.T., Sheppard L.C., McDonald D.A., Estimation of stroke volume in the dog by a pulse contour method, Cir. Res., 26, pp. 611-623, (1970)
[2]  
Ochiai R., Takeda J., Hosaka H., Sugo Y., Tanaka R., Soma T., The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs, J. Clin. Monit. Comput., 15, pp. 493-501, (1999)
[3]  
Balik M., Pachl J., Hendl J., Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution, Intensive Care Med., 28, pp. 1117-1121, (2002)
[4]  
Yelderman M.L., Ramsay M.A., Quinn M.D., Paulsen A.W., McKown R.C., Gillman P.H., Continuous thermodilution cardiac output measurement in intensive care unit patients, J. Cardiothorac. Vasc. Anesth., 6, pp. 270-274, (1992)
[5]  
Siegel L.C., Hennessy M.M., Pearl R.G., Delayed time response of the continuous cardiac output pulmonary artery catheter, Anesth. Analg., 83, pp. 1173-1177, (1996)
[6]  
Lazor M.A., Pierce E.T., Stanley G.D., Cass J.L., Halpern E.F., Bode R.H., Evaluation of the accuracy and response time of Stat-Mode continuous cardiac output, J. Cardiothorac. Vasc. Anesth., 11, pp. 432-436, (1997)
[7]  
Della Rocca G., Costa M.G., Pompei L., Coccia C., Pietropaoli P., Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique, Br. J. Anaesth., 88, pp. 350-356, (2002)
[8]  
Felbinger T.W., Reuter D.A., Eltzschig H.K., Moerstedt K., Gaedje O., Goetz A.E., Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: Evaluation of a new algorithm, J. Clin. Anesth., 14, pp. 296-301, (2002)
[9]  
Zollner C., Goetz A.E., Weis M., Moerstedt K., Pichler B., Lamm P., Kilger E., Haller M., Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination, Can. J. Anesth., 48, pp. 1143-1147, (2001)
[10]  
Le Tulzo Y., Belghith M., Seguin P., Dall'Ava J., Monchi M., Thomas R., Dhainaut J.F., Reproducibility of thermodilution cardiac output determination in critically ill patients: Comparison between bolus and continuous method, J. Clin. Monit., 12, pp. 379-385, (1996)