Hand-held echocardiography: Added value in clinical cardiological assessment

被引:28
作者
Giannotti G. [1 ]
Mondillo S. [1 ]
Galderisi M. [2 ]
Barbati R. [1 ]
Zacà V. [1 ]
Ballo P. [3 ]
Agricola E. [4 ]
Guerrini F. [1 ]
机构
[1] Division of Cardiology, University of Siena
[2] Division of Cardiology, University Federico II, Naples
[3] Division of Cardiology, La Spezia
[4] Division of Non-Invasive Cardiology, Cardiothoracic Department, San Raffaele Hospital, Milano
关键词
echocardiography; Hand Held Device; Standard Echocardiographic Device; conclusiveness; agreement;
D O I
10.1186/1476-7120-3-7
中图分类号
学科分类号
摘要
Background: The ultrasonic industry has recently produced echocardiographic Hand Held Devices (miniaturized, compact and battery-equipped echocardiographic systems). Their potential usefulness has been successfully assessed in a wide range of clinical conditions. The aim of the study was to verify if the routine use of a basic model of echocardiographic Hand Held Device (HHD) could be an important diagnostic tool during outpatient cardiologic consulting or in non-cardiologic hospital sections. Methods: 87 consecutive patients were included in this study; they underwent routine physical examination, resting ECG and echocardiographic evaluation using a basic model of HHD performed by trained echocardiographists; the cardiologist, whenever possible, formulated a diagnosis. The percentage of subjects in whom the findings were judged reasonably adequate for final diagnostic and therapeutic conclusions was used to quantify the "conclusiveness" of HHD evaluation. Successively, all patients underwent a second echocardiographic evaluation, by an examiner with similar echocardiographic experience, performed using a Standard Echo Device (SED). The agreement between the first and the second echocardiographic exam was also assessed. Results: Mean examination time was 6.7 ± 1.5 min. using HHD vs. 13.6 ± 2.4 min. using SED. The echocardiographic examination performed using HHD was considered satisfactory in 74/87 patients (85.1% conclusiveness). Among the 74 patients for whom the examination was conclusive, the diagnosis was concordant with that obtained with the SED examination in 62 cases (83.8% agreement). Conclusion: HHD may generally allow a reliable cardiologic basic evaluation of outpatient or subjects admitted to non-cardiologic sections, more specifically in particular subgroups of patients, with a gain in terms of time, shortening patient waiting lists and reducing healthy costs. © 2005 Giannotti et al; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 23 条
[1]  
Spencer K.T., Anderson A.S., Bhargava A., Bales A.C., Sorrentino M., Furlong K., Lang R.M., Physician Performed Point-of-Care Echocardiography using a Laptop Platform Compared with Phisical Examination in the Cardiovascular Patient, J Am Coll Cardiol, 37, pp. 2013-2018, (2001)
[2]  
Fedson S., Neithardt G., Thomas P., Lickerman A., Radzienda M., DeCara J.M., Lang R.M., Spencer K.T., Unsuspected clinically important findings detected with a small portable ultrasound device in patients admitted to a general medicine service, J Am Soc Echocardiogr, 16, pp. 901-905, (2003)
[3]  
Rugolotto M., Hu B.S., Liang D.H., Schnittger I., Rapid assessment of cardiac anatomy and function with a new hand-carried ultrasound device (Opti-Go): A comparison with standard echocardiography, Eur J Echocardiogr, 2, pp. 262-269, (2001)
[4]  
Vourvouri E.C., Poldermans D., De Sutter J., Sozzi F.B., Izzo P., Roelandt J.R.T.C., Experience with an Ultrasound Stethoscope, J Am Soc Echocardiogr, 15, pp. 80-85, (2002)
[5]  
Kimura B.J., Amundson S.A., Willis C.L., Gilpin E.A., DeMaria A.N., Usefulness of a hand-held ultrasound device for bedside examination of left ventricular function, Am J Cardiol, 90, pp. 1038-1039, (2002)
[6]  
Vourvouri E.C., Poldermans D., Schinkel A.F., Koroleva L.Y., Sozzi F.B., Parharidis G.E., Bax J.J., Roelandt J.R., Left ventricular hypertrophy screening using a hand-held ultrasound device, Eur Heart J, 23, pp. 1516-1521, (2002)
[7]  
Vourvouri E.C., Poldermans D., Schinkel A.F., Sozzi F.B., Bax J.J., Van Urk H., Roelandt J.R., Abdominal aneurysm screening using a hand-held ultrasound device. "A pilot study, Eur J Vasc Endovasc Surg, 22, pp. 352-354, (2001)
[8]  
Bruce C.J., Spittell P.C., Montgomery S.C., Bailey K.R., Tajik A.J., Seward J.B., Personal ultrasound imager: Abdominal aortic aneurysm screening, J Am Soc Echocardiogr, 13, pp. 674-679, (2000)
[9]  
Alexander J.H., Peterson E.D., Chen A.Y., Feasibility of point-of-care echo by non-cardiologist physician to assess left ventricular function, pericardial effusion, mitral regurgitation and aortic valve thickening, Circulation, 104, 2, (2001)
[10]  
Kimura J.B., Amundson S.A., Gilpin E.A., Briefly-trained physician can use a hand-held ultrasound device to improve detection of LV disfunction, Circulation, 104, 2, (2001)