Comparison of Blood Gas Values in Arterial and Venous Blood

被引:27
作者
Chellam Kirubakaran
J. Ebor Jacob Gnananayagam
E. Kalaranjini Sundaravalli
机构
[1] Department of Child Health, Christian Medical College, Vellore
[2] Dept. of Child Health - Unit II, Christian Medical College
关键词
Arterial; Arterialized capillary; Pediatric Intensive Care Unit; Pulse oximetry; Venous blood gas analysis;
D O I
10.1007/BF02723794
中图分类号
学科分类号
摘要
Objective: To compare pH and PCO2 values of simultaneously obtained arterial, arterialized capillary, and venous blood samples and also to compare oxygen saturation (ASaO2) measured in arterial blood and oxygen saturation by pulse oximetry (PSaO2). Methods: Prospective study was done in the children admitted in the Pediatric Intensive Care Unit of Christian Medical College Hospital Vellore, requiring critical care. All the three blood gas samples (arterial, capillary and venous) were taken simultaneously and analyzed. Oxygen saturation by pulse oximetry was also recorded. Results: 50 children aged 14 days to 12 years were included in the study. Arterial and capillary pH values were highly correlated (r 2=0.9024, p<0.0001). Out of 16 children with arterial acidosis 9(56%) were identified by capillary blood gas. Arterial and venous pH values also showed good correlation (r2=0.8449, p<0.0001). The PCO 2 values of arterial and capillary blood gases were found to be highly correlated (r2=0.9534, p<0.0001). The capillary blood gas accurately reflected the arterial PCO2 in 41 (82%) patients. Arterial and venous blood gas PCO2 values had less correlation (r2=0.5917, p=0.011). The arterial oxygen saturation (ASaO 2) and oxygen saturation by pulse oximetry (PSaO2) were correlated moderately (r2=0.7241, p<0.0001). Conclusion: Even though arterial blood gas analysis is the gold standard, and when an arterial blood gas sample cannot be obtained, a combination of arterialized capillary blood gas and pulse oximetry can be effectively used in acutely ill children of all ages. Venous samples have a good correlation with arterial samples for pH but are not useful for monitoring blood gas status in acutely ill children.
引用
收藏
页码:781 / 785
页数:4
相关论文
共 23 条
[1]  
Sherry E., Courtney M.D., Kaye R., Lee A., Et al., Capillary blood gases in the neonate. A reassessment and review of the literature, Am J Dis Child, 144, pp. 168-172, (1990)
[2]  
Siggaard-Anderson O., Acid-base and blood gas parameters: Arterial or capillary blood?, Clin Lab Invest, 21, pp. 289-292, (1968)
[3]  
Donner A., Eliasziw M., Sample size requirements for reliability studies, Statistics in Medicine, 6, pp. 441-448, (1987)
[4]  
Landis J.R., Koch G.G., The measurement of observer agreement for categorical data, Biometrics, 33, pp. 159-174, (1977)
[5]  
Karna P., Poland R., Monitoring critically ill newborn infants with digital Capillary blood samples: An alternative, J Paediatr, 92, pp. 270-273, (1978)
[6]  
Desai S.D., Holoway R., Thambiran A.K., Wesley A.G., A comparison between arterial and arterialized capillary blood in infant, S Afr Med J, 41, pp. 13-15, (1967)
[7]  
Glasgow J.F.T., Flynn D.M., Swyen P.R., A comparison of descending aortic and 'arterialized' capillary blood in the sick newborn, Can Med Assoc J, 106, pp. 660-662, (1972)
[8]  
MacRae O.J., Palavradji O., Comparison between arterial, capillary and venous acid base measurements in the newborn infant, J Obstet Gynaecol Br Common W, 75, pp. 761-765, (1966)
[9]  
Courtney S.E., Kaye R., Breakie L.A., Et al., Capillary blood gases in the neonate. A Reassessment and Review of the literature, Am J Dis Chi, 144, pp. 168-172, (1990)
[10]  
Gandy G., Cunningham N.G., Et al., The validity of pH and PCO2 measurements in capillary samples in sick and healthy newborn infants, Pediatrics, 34, pp. 192-197, (1964)