Cumulative radiation exposure with EOS imaging compared with standard spine radiographs

被引:46
作者
Luo T.D. [1 ]
Stans A.A. [1 ]
Schueler B.A. [2 ]
Larson A.N. [1 ]
机构
[1] Department of Orthopedic Surgery, Mayo Clinic, 200 1st Street SW, Rochester, 55905, MN
[2] Department of Radiology, Mayo Clinic, 200 1st Street SW, Rochester, 55905, MN
关键词
EOS; Radiation exposure; Scoliosis;
D O I
10.1016/j.jspd.2014.09.049
中图分类号
学科分类号
摘要
Study Design Retrospective comparative study. Objectives This study sought to estimate the total radiation exposure to scoliosis patients during the entire treatment course using standard imaging techniques versus EOS posteroanterior (PA) and anteroposterior (AP) views. Summary of Background Data EOS is a slot-scanning X-ray system designed to reduce radiation exposure in orthopedic imaging. There are few independent studies comparing organ and total effective radiation dose from standard EOS PA, AP, and lateral imaging versus conventional projection radiographs for children with spinal deformity. Methods A total of 42 skeletally immature idiopathic scoliosis patients were treated with bracing (21) or spinal fusion (21) and were followed to skeletal maturity. The number of scoliosis radiographs (PA and lateral) for each patient was recorded. A computerized dosing model was used to calculate estimated patient and organ doses for PA and lateral scoliosis X-rays taken with EOS or computed radiography with a filter (CR) or without a filter (CRF). Assuming that each X-ray taken delivered the same radiation as the phantom calculation, the authors estimated the total effective and organ dose that each adolescent would have received using EOS, CR, or CRF. Annual background radiation is 3 mSv. Results Mean number of radiographs per patient was 20.9 (range, 8-43). Patients who underwent surgical treatment had a significantly greater number of X-rays than those who were braced (27.3 vs. 14.5; p <.001). Assuming all films were CR, the mean cumulative dose was estimated at 5.38 mSv. With standard EOS films, the mean cumulative estimated dose was 2.66 mSv, a decrease of 50.6%. An AP versus PA EOS radiograph resulted in an 8 times higher radiation dose to the breasts and 4 times higher dose to the thyroid. Conclusions The standard EOS imaging system moderately reduced the total radiation exposure to skeletally immature scoliosis patients. Over the entire treatment course, this represented 2.72 mSv mean reduction or 0.91 years of background radiation. Posteroanterior films significantly reduced breast and thyroid dose. © 2015 Scoliosis Research Society.
引用
收藏
页码:144 / 150
页数:6
相关论文
共 31 条
[1]
Cannon T.A., Neto N.A., Kelly D.M., Characterization of radiation exposure in early-onset scoliosis patients treated with the vertical expandable prosthetic titanium rib (VEPTR), J Pediatr Orthop, 34, pp. 179-184, (2014)
[2]
Sharp N.E., Raghavan M.U., Svetanoff W.J., Radiation exposure - How do CT scans for appendicitis compare between a free standing children's hospital and non-dedicated pediatric facilities?, J Pediatr Surg, 49, pp. 1016-1019, (2014)
[3]
Hawking N.G., Sharp T.D., Decreasing radiation exposure on pediatric portable chest radiographs, Radiol Technol, 85, pp. 9-16, (2013)
[4]
Stokes O.M., O'Donovan E.J., Samartzis D., Reducing radiation exposure in early-onset scoliosis surgery patients: Novel use of ultrasonography to measure lengthening in magnetically-controlled growing rods, Spine J, 14, pp. 2397-2404, (2014)
[5]
Ungi T., King F., Kempston M., Spinal curvature measurement by tracked ultrasound snapshots, Ultrasound Med Biol, 40, pp. 447-454, (2014)
[6]
Vila-Casademunt A., Pellise F., Domingo-Sabat M., Is routine postoperative radiologic follow-up justified in adolescent idiopathic scoliosis?, Spine Deformity, 1, pp. 223-228, (2013)
[7]
Garg S., Kipper E., Lagreca J., Are routine postoperative radiographs necessary during the first year after posterior spinal fusion for idiopathic scoliosis? A retrospective cohort analysis of implant failure and surgery revision rates, J Pediatr Orthop, (2014)
[8]
Dietrich T.J., Pfirrmann C.W., Schwab A., Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography, Skeletal Radiol, 42, pp. 959-967, (2013)
[9]
Ilharreborde B., Steffen J.S., Nectoux E., Angle measurement reproducibility using EOS three-dimensional reconstructions in adolescent idiopathic scoliosis treated by posterior instrumentation, Spine (Phila Pa 1976), 36, pp. E1306-E1313, (2011)
[10]
Monnin P., Holzer Z., Wolf R., An image quality comparison of standard and dual-side read CR systems for pediatric radiology, Med Phys, 33, pp. 411-420, (2006)