Reliability of the biceps brachii M-wave

被引:39
作者
Calder K.M. [1 ]
Hall L.-A. [1 ]
Lester S.M. [1 ]
Inglis J.G. [1 ]
Gabriel D.A. [1 ]
机构
[1] Electromyographic Kinesiology Laboratory, Faculty of Applied Helath Science, Brock University, St.Catharines, Ont. L2S 3A1
关键词
Compound muscle action potential; intraclass correlation coefficient; electromyographic activity;
D O I
10.1186/1743-0003-2-33
中图分类号
学科分类号
摘要
Background: The peak-to-peak (P-P) amplitude of the maximum M-wave and the area of the negative phase of the curve are important measures that serve as methodological controls in H-reflex studies, motor unit number estimation (MUNE) procedures, and normalization factors for voluntary electromyographic (EMG) activity. These methodologies assume, with little evidence, that M-wave variability is minimal. This study therefore examined the intraclass reliability of these measures for the biceps brachii. Methods: Twenty-two healthy adults (4 males and 18 females) participated in 5 separate days of electrical stimulation of the musculocutaneous nerve supplying the biceps brachii muscle. A total of 10 stimulations were recorded on each of the 5 test sessions: a total of fifty trials were used for analysis. A two-factor repeated measures analysis of variance (ANOVA) evaluated the stability of the group means across test sessions. The consistency of scores within individuals was determined by calculating the intraclass correlation coefficient (ICC). The variance ratio (VR) was then used to assess the reproducibility of the shape of the maximum M-wave within individual subjects. Results: The P-P amplitude means ranged from 12.62 ± 4.33 mV to 13.45 ± 4.07 mV across test sessions. The group means were highly stable. ICC analysis also revealed that the scores were very consistent (ICC = 0.98). The group means for the area of the negative phase of the maximum M-wave were also stable (117 to 126 mV·ms). The ICC analysis also indicated a high degree of consistency (ICC = 0.96). The VR for the sample was 0.244 ± 0.169, which suggests that the biceps brachii maximum M-wave shape was in general very reproducible for each subject. Conclusion: The results support the use of P-P amplitude of the maximum M-wave as a methodological control in H-reflex studies, and as a normalization factor for voluntary EMG. The area of the negative phase of the maximum M-wave is both stable and consistent, and the shape of the entire waveform is highly reproducible and may be used for MUNE procedures. © 2005 Calder et al; licensee BioMed Central Ltd.
引用
收藏
页码:1 / 8
页数:7
相关论文
共 27 条
[1]
Maffiuletti N.A., Martin A., Babault N., Pensini M., Lucas B., Schieppati M., Electrical and mechanical H<sub>max</sub>-to-M<sub>max</sub> ratio in power- and endurance-trained athletes, J Appl Physiol, 90, pp. 3-9, (2001)
[2]
Aagaard P., Simonsen E.B., Andersen J.L., Magnusson P., Dyhre-Poulsen P., Neural adaptation to resistance training: Changes in evoked V-wave and H-reflex responses, J Appl Physiol, 92, pp. 2309-2318, (2002)
[3]
Crone C., Johnsen L.L., Hultborn H., Ornes G.B., Amplitude of the maximum motor response (Mmax) in human muscles typically decreases during the course of an experiment, Exp Brain Res, 124, pp. 265-270, (1999)
[4]
Boe S., Stashuk D.W., Doherty T.J., Motor unit number estimation by decomposition-enhanced spike-triggered averaging: Control data, test-retest reliability, and contractile level effects, Muscle Nerve, 29, pp. 693-699, (2004)
[5]
Scaglioni G., Ferri A., Minetti A.E., Martin A., Van Hoeck J., Capodaglio P., Sartorio A., Narci M.V., Plantar flexor activation capacity and H reflex in older adults: Adaptations to strength training, J Appl Physiol, 92, pp. 2292-2302, (2002)
[6]
Carolan B., Cafarelli E., Adaptations in coactivation after isometric resistance training, J Appl Physiol, 73, pp. 911-917, (1992)
[7]
Rich C., Cafarelli E., Submaximal motor unit firing rates after 8 wk of isometric resistance training, Med Sci Sport Exerc, 32, pp. 190-196, (2000)
[8]
Jaberzadeh S., Scutter S., Warden-Flood A., Nazeran H., Between-days reliability of H- reflexes in human flexor carpi radialis, Arch Phys Med Rehabil, 85, pp. 1168-1173, (2004)
[9]
Shefner J.M., Jillapalli D., Bradshaw D.Y., Reducing intersubject variability in motor unit number estimation, Muscle Nerve, 22, pp. 1457-1460, (1999)
[10]
Williams L.R.T., Sullivan S.J., Seaborne D.E., Morelli M., Reliability of individual differences for H-reflex recordings, Electromyogr Clin Neurophysiol, 32, pp. 42-49, (1992)