RELIABILITY OF GONIOMETRIC MEASUREMENTS AND VISUAL ESTIMATES OF KNEE RANGE OF MOTION OBTAINED IN A CLINICAL SETTING

被引:228
作者
WATKINS, MA
RIDDLE, DL
LAMB, RL
PERSONIUS, WJ
机构
[1] VIRGINIA COMMONWEALTH UNIV,MED COLL VIRGINIA,SCH ALLIED HLTH PROFESS,DEPT PHYS THERAPY,RICHMOND,VA 23298
[2] SHENANDOAH COLL & CONSERVATORY,WINCHESTER MED CTR,DEPT PHYS THERAPY,WINCHESTER,VA 22601
来源
PHYSICAL THERAPY | 1991年 / 71卷 / 02期
关键词
KINESIOLOGY BIOMECHANICS; LOWER EXTREMITY; KNEE; TESTS AND MEASUREMENTS; RANGE OF MOTION;
D O I
10.1093/ptj/71.2.90
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to examine the intratester and intertester reliability for goniometric measurements of knee flexion and extension passive range of motion (PROM). In addition, parallel-forms reliability for PROM measurements of the knee obtained by use of a goniometer and by visual estimation was examined. The intertester reliability for visual estimates of the PROM of the knee was also examined. Repeated measurements were obtained on 43 patients in a clinical setting. The intraclass correlation coefficients (ICCs) for intratester reliability of measurements obtained with a goniometer were .99 for flexion and .98 for extension. Intertester reliability for measurements obtained with a goniometer was .90 for flexion and .86 for extension. The ICCs for parallel-forms reliability for measurements obtained with a goniometer and by visual estimation ranged from .82 to .94. The intertester reliability for measurements obtained by visual estimation was .83 for flexion and .82 for extension. Results suggest clinicians should use a goniometer to take repeated PROM measurements of a patient's knee to minimize the error associated with these measurements.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 15 条
[1]   METHODS AND THEORY OF RELIABILITY [J].
BARTKO, JJ ;
CARPENTER, WT .
JOURNAL OF NERVOUS AND MENTAL DISEASE, 1976, 163 (05) :307-317
[2]   GONIOMETRIC RELIABILITY IN A CLINICAL SETTING - SUBTALAR AND ANKLE JOINT MEASUREMENTS [J].
ELVERU, RA ;
ROTHSTEIN, JM ;
LAMB, RL .
PHYSICAL THERAPY, 1988, 68 (05) :672-677
[3]  
KERLINGER FN, 1973, F BEHAVIORAL RES
[4]  
LOVELL FW, 1989, PHYS THER, V69, P96, DOI 10.1093/ptj/69.2.96
[5]   OBSERVER VARIATION IN EXAMINATION OF KNEE JOINTS [J].
MARKS, JS ;
PALMER, MK ;
BURKE, MJ ;
SMITH, P .
ANNALS OF THE RHEUMATIC DISEASES, 1978, 37 (04) :376-377
[6]  
MILLER JP, 1985, MEASUREMENT PHYSICAL, P103
[7]  
Minor MAD, 1985, PATIENT EVALUATION M
[8]  
MOORE M L, 1949, Phys Ther Rev, V29, P195
[9]   GONIOMETRIC RELIABILITY IN A CLINICAL SETTING - SHOULDER MEASUREMENTS [J].
RIDDLE, DL ;
ROTHSTEIN, JM ;
LAMB, RL .
PHYSICAL THERAPY, 1987, 67 (05) :668-673
[10]   GONIOMETRIC RELIABILITY IN A CLINICAL SETTING - ELBOW AND KNEE MEASUREMENTS [J].
ROTHSTEIN, JM ;
MILLER, PJ ;
ROETTGER, RF .
PHYSICAL THERAPY, 1983, 63 (10) :1611-1615