RELIABILITY OF MEASUREMENTS OF CERVICAL-SPINE RANGE OF MOTION - COMPARISON OF 3 METHODS

被引:327
作者
YOUDAS, JW
CAREY, JR
GARRETT, TR
机构
[1] MAYO SCH HLTH RELATED SCI,PHYS THERAPY PROGRAM,ROCHESTER,MN 55905
[2] MAYO CLIN & MAYO GRAD SCH MED,PHYS THERAPY,ROCHESTER,MN 55901
来源
PHYSICAL THERAPY | 1991年 / 71卷 / 02期
关键词
CERVICAL VERTEBRAE; SPINE; TESTS AND MEASUREMENTS; RANGE OF MOTION;
D O I
10.1093/ptj/71.2.98
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To determine reliabilities within and between persons measuring cervical active range of motion (AROM), three methods were examined: use of a cervical-range-of-motion (CROM) instrument, use of a universal goniometer (UG), and visual estimation (VE). Measurements were made on 60 patients with orthopedic disorders of the cervical spine who were divided into three groups of 20 subjects each. All subjects were tested in a standardized seated position using operationally defined goniometric placements and nongoniometric estimation techniques. Cervical flexion and extension, lateral flexion, and rotation were measured. Intraclass correlation coefficients (ICCs) were used to quantify within-tester and between-tester reliability. We found that goniometric measurements of AROM of the cervical spine made by the same physical therapist had ICCs greater than .80 when made with the CROM device or the UG. When different physical therapists measured the same patient's cervical AROM, the CROM device had ICCs greater than .80, whereas the UG and VE generally had ICCs less than .80.
引用
收藏
页码:98 / 104
页数:7
相关论文
共 18 条
  • [1] BLESH TE, 1974, MEASUREMENT PHYSICAL
  • [2] RELIABILITY OF GONIOMETRIC MEASUREMENTS
    BOONE, DC
    AZEN, SP
    LIN, CM
    SPENCE, C
    BARON, C
    LEE, L
    [J]. PHYSICAL THERAPY, 1978, 58 (11): : 1355 - 1360
  • [3] Cole T.M., 1982, KRUSENS HDB PHYS MED, P19
  • [4] CURRIER DP, 1990, ELEMENTS RES PHYS TH, P167
  • [5] Dhir R S, 1971, Clin Orthop Relat Res, V78, P336, DOI 10.1097/00003086-197107000-00030
  • [6] GONIOMETRIC RELIABILITY IN A CLINICAL SETTING - SUBTALAR AND ANKLE JOINT MEASUREMENTS
    ELVERU, RA
    ROTHSTEIN, JM
    LAMB, RL
    [J]. PHYSICAL THERAPY, 1988, 68 (05): : 672 - 677
  • [7] CLINICAL MEASUREMENT OF RANGE OF MOTION - REVIEW OF GONIOMETRY EMPHASIZING RELIABILITY AND VALIDITY
    GAJDOSIK, RL
    BOHANNON, RW
    [J]. PHYSICAL THERAPY, 1987, 67 (12): : 1867 - 1872
  • [8] Low J L, 1976, Physiotherapy, V62, P227
  • [9] MILLER PJ, 1985, MEASUREMENT PHYS THE, P103
  • [10] MOLL JMH, 1976, CLIN RHEUM DIS, V2, P3