GEOGRID CONNECTIONS

被引:8
作者
CARROLL, RG
CHOUERYCURTIS, V
机构
[1] Tensar Earth Technologies, Inc., Morrow, GA 30260
[2] Tensar Environmental Systems, Inc., Morrow, GA 30260
关键词
D O I
10.1016/0266-1144(90)90044-D
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Connections can have a significant impact on the performance of geosynthetic systems whether their intended function is separation or reinforcement. When reinforcement is the function, the connection must be considered as a limiting strength factor and evaluated by the same performance standards as the reinforcement material alone. If used in critical structures with design lives of more than 1 or 2 years, the geosynthetic and its connections must be evaluated for durability limitations such as creep, site damage and chemical degradation. Geogrid connections typically fall into this category. Geogrid connections are accomplished by either overlapping or mechanical connections. Overlap connections must be designed and constructed to assure proper overlap lengths. Overlap length is governed by soil interaction behavior. Geogrid-soil interaction is measured by pull-out testing and pull-out performance is a function of geogrid dimensional stability. Overlaps can be secured by a variety of tyiing techniques but these ties are not efficient for load transfer. Geogrid Bodkin Joints are the preferred mechanical connection for assuring full load transfer between adjacent layers of some geogrids. This paper discusses geogrid connections, the techniques used, and the factors that affect their performance. © 1990.
引用
收藏
页码:515 / 530
页数:16
相关论文
共 9 条
[1]  
Jewell, Milligan, Sorsby, Dubois, Interaction between soil and geogrids, polymer grid reinforcement, Conference Proceedings Sponsored by the Science and Engineering Research Council and Netlon, Ltd, pp. 18-29, (1984)
[2]  
Dyer, Observations of the stress distribution in crushed glass with applications to soil reinforcement, D. Phil. Thesis, (1985)
[3]  
Base Reinforcement Installation Guide, (1987)
[4]  
GRI Test Method: GG3—Creep Behavior and Long-Term Design Load of Georids, (1988)
[5]  
Murray, McGown, Andrawes, Swan, Testing joints in geotextiles and geogrids, Proceedings of the Third International Conference on Geotextiles, pp. 731-736, (1986)
[6]  
Richardson, Behr, Geotextile Reinforced Wall: Failure and Remedy, Geotechnical Fabrics Report, (1988)
[7]  
Koerner, Wayne, Carroll, Analytical behavior of gegrid anchorage, Proceedings of Geosynthetics '89 Conference, San Diego, 2, pp. 525-536, (1989)
[8]  
Berg, Swan, Pullout of geosynthetics (draft) prepared for International Reinforced Soil Conference, (1990)
[9]  
Bush, Netlon, Ltd, Engineering Report—Joining Tensar SR55, SR80, and SR110 Geogrids, (1988)