CALIBRATION OF CSI(TL) SCINTILLATORS FOR HEAVY-IONS (3-LESS-THAN-OR-EQUAL-TO-Z-LESS-THAN-OR-EQUAL-TO-54) IN A WIDE ENERGY-RANGE (E/U-LESS-THAN-OR-EQUAL-TO-60 ME V/U)

被引:29
作者
MASTINU, PF
MILAZZO, PM
BRUNO, M
DAGOSTINO, M
MANDUCI, L
机构
[1] UNIV BOLOGNA, IST NAZL FIS NUCL, SEZ BOLOGNA, I-40126 BOLOGNA, ITALY
[2] UNIV BOLOGNA, DIPARTIMENTO FIS, I-40126 BOLOGNA, ITALY
关键词
D O I
10.1016/0168-9002(94)91325-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The light output response of CsI(TI) scintillators, photodiodes readout, has been investigated for heavy ions with atomic number 3 less than or equal to Z less than or equal to 54 for energies up to 45 MeV/u. The detectors have been calibrated with particular attention to the dependence on the atomic number of the ions. The expression obtained with this procedure was applied to the calibration of the CsI(TI) detectors of the MULTICS array, on the basis of only one renormalization coefficient. A complete compatibility has been found with recent data at energies up to 60 MeV/u.
引用
收藏
页码:419 / 424
页数:6
相关论文
共 20 条
[1]  
ANDERSON HH, 1977, STOPPING POWER RANGE
[2]  
[Anonymous], 1964, THEORY PRACTICE SCIN
[3]  
Bethe H, 1930, ANN PHYS-BERLIN, V5, P325
[4]  
BREUER H, 1982, PHYS LETT C, V26, P178
[5]   PRODUCTION OF 3 NEARLY EQUAL MASS FRAGMENTS IN THE XE+CU REACTION AT 45 MEV/U [J].
BRUNO, M ;
DAGOSTINO, M ;
FIANDRI, ML ;
FUSCHINI, E ;
MILAZZO, PM ;
CUNSOLO, A ;
FOTI, A ;
GRAMEGNA, F ;
GULMINELLI, F ;
IORI, I ;
MANDUCI, L ;
MORONI, A ;
SCARDAONI, R ;
BUTTAZZO, P ;
MARGAGLIOTTI, GV ;
VANNINI, G ;
AUGER, G ;
PLAGNOL, E .
PHYSICS LETTERS B, 1992, 292 (3-4) :251-256
[6]   EFFICIENCY OF A LARGE SOLID ANGLE DETECTING SYSTEM FOR HEAVY-IONS [J].
BRUNO, M ;
DAGOSTINO, M ;
MILAZZO, PM ;
OSTUNI, S ;
FUSCHINI, E ;
MORONI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (02) :410-414
[7]   RESPONSE OF PILOT-U SCINTILLATOR TO HEAVY-IONS [J].
BUENERD, M ;
HENDRIE, DL ;
JAHNKE, U ;
MAHONEY, J ;
MENCHACAROCHA, A ;
OLMER, C ;
SCOTT, DK .
NUCLEAR INSTRUMENTS & METHODS, 1976, 136 (01) :173-177
[8]   CHARACTERIZATION OF HOT COMPOUND NUCLEI FROM BINARY DECAY INTO COMPLEX FRAGMENTS [J].
CHARITY, RJ ;
MCMAHAN, MA ;
BOWMAN, DR ;
LIU, ZH ;
MCDONALD, RJ ;
WOZNIAK, GJ ;
MORETTO, LG ;
BRADLEY, S ;
KEHOE, WL ;
MIGNEREY, AC ;
NAMBOODIRI, MN .
PHYSICAL REVIEW LETTERS, 1986, 56 (13) :1354-1357
[9]   CALIBRATION OF THE RESPONSE FUNCTION OF CSI(TL) SCINTILLATORS TO INTERMEDIATE-ENERGY HEAVY-IONS [J].
COLONNA, N ;
WOZNIAK, GJ ;
VEECK, A ;
SKULSKI, W ;
GOTH, GW ;
MANDUCI, L ;
MILAZZO, PM ;
MASTINU, PF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 321 (03) :529-534
[10]   THE MSU MINIBALL 4-PI FRAGMENT DETECTION ARRAY [J].
DESOUZA, RT ;
CARLIN, N ;
KIM, YD ;
OTTARSON, J ;
PHAIR, L ;
BOWMAN, DR ;
GELBKE, CK ;
GONG, WG ;
LYNCH, WG ;
PELAK, RA ;
PETERSON, T ;
POGGI, G ;
TSANG, MB ;
XU, HM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 295 (1-2) :109-122