A PROSPECTIVE, RANDOMIZED COMPARISON OF THERMAL CAUTERY AND ARGON-LASER FOR PERMANENT PUNCTAL OCCLUSION

被引:18
作者
VRABEC, MP [1 ]
ELSING, SH [1 ]
AITKEN, PA [1 ]
机构
[1] UNIV VERMONT,COLL MED,DEPT SURG,DIV OPHTHALMOL,BURLINGTON,VT 05405
关键词
D O I
10.1016/S0002-9394(14)71406-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Permanent punctal occlusion was performed by two techniques on 27 patients (73 puncta). Patients were randomly assigned to be treated with either thermal cautery or argon laser for keratitis sicca. Follow-up assessment disclosed that the puncta to which thermal cautery was applied remained closed significantly longer than those to which laser treatment was applied (P < .05, log-rank test). Using time to recanalization of a punctum as the end point, we found a long-term advantage of thermal cautery over argon laser treatment.
引用
收藏
页码:469 / 471
页数:3
相关论文
共 4 条
[1]  
Carter K D, 1988, Ophthalmic Plast Reconstr Surg, V4, P231, DOI 10.1097/00002341-198804040-00006
[2]   A COMPARISON OF 2 METHODS OF PUNCTAL OCCLUSION [J].
KNAPP, ME ;
FRUEH, BR ;
NELSON, CC ;
MUSCH, DC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (03) :315-318
[3]  
LEMP MA, 1987, OPHTHALMOLOGY, V94, P1299
[4]   DESIGN AND ANALYSIS OF RANDOMIZED CLINICAL-TRIALS REQUIRING PROLONGED OBSERVATION OF EACH PATIENT .2. ANALYSIS AND EXAMPLES [J].
PETO, R ;
PIKE, MC ;
ARMITAGE, P ;
BRESLOW, NE ;
COX, DR ;
HOWARD, SV ;
MANTEL, N ;
MCPHERSON, K ;
PETO, J ;
SMITH, PG .
BRITISH JOURNAL OF CANCER, 1977, 35 (01) :1-39