THE CLINICAL UTILITY OF AMBULATORY CASSETTE EEG

被引:45
作者
BRIDGERS, SL [1 ]
EBERSOLE, JS [1 ]
机构
[1] YALE UNIV, SCH MED, DEPT NEUROL, NEW HAVEN, CT 06510 USA
关键词
D O I
10.1212/WNL.35.2.166
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Ambulatory EEG monitoring (A/EEG) was obtained before intensive monitoring in 33 patients newly referred to an epilepsy center. The A/EEG yield of evidence to support a diagnosis of epilepsy was 83% of that of intensive monitoring and 2.5 times that of routine EEG. Accuracy of A/EEG analysis was confirmed by 2 blind reviews for each tape, with only 3 misreadings among 99 interpretations rendered. Among 25 patients with specifically diagnostic referrals, A/EEG served the purpose of admission as well as intensive monitoring in 60%. Episodes not accompanied by A/EEG change required behavioral observation for correct identification.
引用
收藏
页码:166 / 173
页数:8