QUANTITATIVE HISTOLOGIC EVALUATION OF LTI CARBON, CARBON-COATED ALUMINUM-OXIDE AND UNCOATED ALUMINUM-OXIDE DENTAL IMPLANTS

被引:21
作者
COOK, SD [1 ]
WEINSTEIN, AM [1 ]
KLAWITTER, JJ [1 ]
KENT, JN [1 ]
机构
[1] LOUISIANA STATE UNIV,SCH DENT,DEPT ORAL & MAXILLOFACIAL SURG,NEW ORLEANS,LA 70119
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1983年 / 17卷 / 03期
关键词
ALUMINA - Medical Applications - BIOLOGICAL MATERIALS - Tissue - CARBON - Medical Applications;
D O I
10.1002/jbm.820170311
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The response of mandibular bone to identical geometry LTI (Low Temperature Isotropic) carbon, carbon-coated aluminum oxide, and uncoated aluminum oxide blade-type dental implants in baboons for 2 years was evaluated using histologic, microradiographic, and scanning electron microscopic methods. In addition, a quantitative histologic analysis was performed identifying the type, amount, and distribution of tissue surrounding the dental implant systems. This is the final phase of a study investigating the effect of implant elastic modulus and implant surface chemical composition on the performance of dental implants. The results indicate that significant stress shielding of the crestal bone had occurred with the rigid carbon-coated and uncoated aluminum oxide implants when compared to the LTI carbon implants which had a material elastic modulus similar to cortical bone. Based upon the histologic results, it appears that the LTI carbon implants with the direct implant-bone interface exhibited a greater potential for long-term successful performance compared to the aluminum oxide substrate implants.
引用
收藏
页码:519 / 538
页数:20
相关论文
共 29 条
[1]  
ANDERSON R, 1982, 28TH T ANN M ORTH RE, V7, P178
[2]  
ARMITAGE JE, 1980, 811531 US DEP HLTH H, P294
[3]  
BOKROS JC, 1977, CARBON, V15, P355, DOI 10.1016/0008-6223(77)90324-4
[4]   PARAMETERS AFFECTING THE STRESS-DISTRIBUTION AROUND LTI CARBON AND ALUMINUM-OXIDE DENTAL IMPLANTS [J].
COOK, SD ;
WEINSTEIN, AM ;
KLAWITTER, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (06) :875-885
[5]   THE INFLUENCE OF IMPLANT GEOMETRY ON THE STRESS-DISTRIBUTION AROUND DENTAL IMPLANTS [J].
COOK, SD ;
KLAWITTER, JJ ;
WEINSTEIN, AM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (04) :369-379
[6]   THE INFLUENCE OF IMPLANT ELASTIC-MODULUS ON THE STRESS-DISTRIBUTION AROUND LTI CARBON AND ALUMINUM-OXIDE DENTAL IMPLANTS [J].
COOK, SD ;
KLAWITTER, JJ ;
WEINSTEIN, AM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1981, 15 (06) :879-887
[7]  
COOK SD, 1983, J BIOMED MATER RES
[8]   STATISTICAL EVALUATION OF 952 ENDOSTEAL IMPLANTS IN HUMANS [J].
CRANIN, AN ;
RABKIN, MF ;
GARFINKEL, L .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1977, 94 (02) :315-320
[9]  
DIXON WJ, 1979, BMDP79 BIOMEDICAL CO
[10]  
DRISKELL TD, 1977, ORAL IMPLANTOL, V7, P53