PULSE RADAR TECHNIQUE FOR REFLECTOMETRY ON THERMONUCLEAR PLASMAS

被引:46
作者
HUGENHOLTZ, CAJ
HEIJNEN, SH
机构
[1] FOM-Instituut voor Plasmafysica Rijnhuizen, Associatie Euratom-FOM, 3430 BE Nieuwegein
关键词
D O I
10.1063/1.1142014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
new method to measure density profiles of thermonuclear plasmas with fast pulse radar is proposed. A number of important benefits of pulse radar above the generally used swept frequency reflectometry are given. A test bench experiment at 34 GHz, using pulses with 1.5-ns rise and fall times, showed that a spatial accuracy of about 1 mm can be reached. With ultrafast (200 ps) microwave pulses it is perhaps possible to perform a direct measurement of the density gradient of the plasma from the broadening and the modification of the shape of the reflected pulse.
引用
收藏
页码:1100 / 1101
页数:2
相关论文
共 6 条
[1]  
DONNE AJH, 1989, RR89187
[2]  
HUGENHOLTZ CAJ, 1990, FOM90192 I PLASM RIJ
[3]  
PAVLICHENKO OS, 1990, ITERILPH07015
[4]  
PRENTICE R, 1990, 17TH P EUR C CONTR F, P1500
[6]  
TOMABECHI K, 1908, 12TH P INT C PLASM P, V3, P215