CONCERNING THE TOXICITY OF 2 COMPOUNDS USED AS MEDIATORS IN BIOSENSOR DEVICES - 7,7,8,8-TETRACYANOQUINODIMETHANE (TCNQ) AND TETRATHIAFULVALENE (TTF)

被引:17
作者
KULYS, J
SIMKEVICIENE, V
HIGGINS, IJ
机构
[1] CRANFIELD INST TECHNOL, CTR BIOTECHNOL, CRANFIELD MK43 0AL, BEDS, ENGLAND
[2] CRANFIELD INST TECHNOL, CTR BIOTECHNOL, CRANFIELD MK43 0AL, BEDS, ENGLAND
[3] VILNIUS BIOCHEM INST, VILNIUS 2600, LITHUANIA, USSR
关键词
7,7,8,8-TETRACYANOQUINODIMETHANE; TETRATHIAFULVALENE; TOXICITY;
D O I
10.1016/0956-5663(92)80006-W
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The lethal dose (LD50) and the maximum tolerated dose (MTD) of TCNQ and TTF were determined experimentally by single-dose administration to CBA-line mice. The effect of the compounds on the blood constitution, accumulation, acute and subacute dermal and eye irritation, skin sensitization and delayed type hypersensitivity reaction were also monitored in mice and guinea pigs. The LD50s were found to be 1225 mg kg-1 (6.0 mmol kg-1) for TCNQ and 710 mg kg-1 (3.5 mmol kg-1) for TTF; MTDs were 750 mg kg-1 (3-7 mmol kg-1) and 450 mg kg-1 (2-2 mmol kg-1), respectively. Mice that had received the MTD showed no significant change in their measured blood parameters after five days for TTF; however, for TCNQ a decrease in the absolute leucocyte number and changes in the leucoformula were apparent by the fifth day. Oral administration to mice for 28 days at a concentration of 10% of the LD50 showed a super-accumulation, and the accumulation index was 0-94 and 0-53 for TCNQ and TTF, respectively. Neither compound caused acute or subacute dermal irritation of guinea pigs and there was no acute eye irritation. Skin sensitization in guinea pigs and delayed-type hypersensitivity reaction in mice indicated that TCNQ and TTF used as ethanol solutions were not allergic. This study indicates that TCNQ and TTF may be regarded as low-toxicity compounds.
引用
收藏
页码:495 / 501
页数:7
相关论文
共 15 条
[1]  
ASTON WJ, 1987, BIOSENSORS FUNDAMENT, P276
[2]  
Belenkii M.L, 1963, ELEMENTY KOLICHESTVE, P81
[3]  
CARDOSI MF, 1987, BIOSENSORS FUNDAMENT, P257
[4]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[5]   BIOCATALYTIC OXIDATION OF GLUCOSE ON THE CONDUCTIVE CHARGE-TRANSFER COMPLEXES [J].
CENAS, NK ;
KULYS, JJ .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1981, 8 (01) :103-113
[6]   ELECTROCATALYTIC OXIDATION OF ASCORBIC-ACID AT CHEMICALLY MODIFIED ELECTRODES [J].
KULYS, J ;
DRUNGILIENE, A .
ELECTROANALYSIS, 1991, 3 (03) :209-214
[7]   CHEMICALLY MODIFIED ELECTRODES FOR THE DETERMINATION OF SULFHYDRYL COMPOUNDS [J].
KULYS, J ;
DRUNGILIENE, A .
ANALYTICA CHIMICA ACTA, 1991, 243 (02) :287-292
[8]   PRINTED AMPEROMETRIC SENSOR BASED ON TCNQ AND CHOLINESTERASE [J].
KULYS, J ;
DCOSTA, EJ .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) :109-115
[9]   BIENZYME SENSORS BASED ON CHEMICALLY MODIFIED ELECTRODES [J].
KULYS, J ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (01) :43-48
[10]  
LENGA RE, 1988, SIGMA ALDRICH LIBRAR, V2, P1681