WORK AND HEAT FLOWS IN A PULSE-TUBE REFRIGERATOR

被引:7
作者
KASUYA, M
NAKATSU, M
GENG, Q
YUYAMA, J
GOTO, E
机构
[1] Quantum Magneto Flux Logic Project, ERATO, Research Development Corporation of Japan, Chigasaki, Kanagawa, 253
关键词
REFRIGERATION; PULSE-TUBE REFRIGERATORS; HEAT TRANSFER;
D O I
10.1016/0011-2275(91)90135-J
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper reports a study on the role of heat exchange between the gases in the pulse tube and the tube wall in a pulse-tube refrigerator. To this end, the work flow going through the pulse tube without heat exchange is experimentally studied by mounting a piston on the hot end of the pulse tube. Refrigeration power is found to increase as the work flow reaching the hot-end piston increases. On the contrary, the heat flow released into a room temperature environment decreases as the work flow increases. This suggests that the work flow becomes more important as the refrigeration power increases.
引用
收藏
页码:786 / 790
页数:5
相关论文
共 7 条
[1]  
GIFFORD WE, 1966, ADV CRYOGEN ENG, V11, P171
[2]  
MATSUBARA Y, 1988, 5TH P INT CRYOC C MO, P127
[3]  
Mikulin E.I., 1984, ADV CRYOGEN ENG, V29, P629, DOI DOI 10.1007/978-1-4613-9865-3_72
[4]  
Radebaugh R, 1986, ADV CRYOGEN ENG, V31, P779, DOI DOI 10.1007/978-1-4613-2213-9_88/COVER
[5]   THERMOACOUSTIC ENGINES [J].
SWIFT, GW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 84 (04) :1145-1180
[6]  
TOMINAGA A, 1989, 3RD P JAP SIN JOINT, P141
[7]  