EFFECT OF POLYOL TYPE ON THE SURFACE-STRUCTURE OF SULFONATE-CONTAINING POLYURETHANES

被引:34
作者
SILVER, JH
LEWIS, KB
RATNER, BD
COOPER, SL
机构
[1] UNIV WISCONSIN,DEPT CHEM ENGN,MADISON,WI 53706
[2] UNIV WASHINGTON,CTR BIOENGN,SEATTLE,WA 98195
[3] UNIV WASHINGTON,NATL ESCA & SURFACE ANAL CTR BIOMED PROBLEMS,SEATTLE,WA 98195
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1993年 / 27卷 / 06期
关键词
D O I
10.1002/jbm.820270606
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyurethanes based upon polytetramethylene oxide (PTMO) as the polyol and derivatized with propyl sulfonate functionality pendant from the urethane nitrogen have previously been shown to possess good blood-contacting properties. Other investigators have shown that sulfonated polyurethanes containing polyethylene oxide (PEO) as the soft segment are much more thrombogenic than those containing PTMO as the soft segment. In this article, the surface properties of sulfonated polyurethanes based upon either PTMO or PEO are compared. Dynamic contact angle measurements show a significant decrease in the receding angles of the sulfonated PTMO-containing polyurethane as compared to its nonsulfonated precursor polymer. No significant difference is seen between the receding contact angles of either the sulfonated PEO-based polyurethane or its nonsulfonated analog. Variable-angle electron spectroscopy for chemical analysis (ESCA) studies of sulfonated PTMO-based polyurethane performed at room temperature show that there is a significant decrease in sulfur content at the surface. In contrast, the sulfonated PEO-based polyurethane showed little change in sulfur content with take-off angle. Finally, ESCA studies of freeze-dried surfaces show a significant increase in sulfur near the surface of the sulfonated PTMO-based polymer as compared to vacuum-dried samples but show no such increase for the sulfonated PEO-based polyurethane. It is suggested that the ability of the sulfonate functionality to be expressed at the surface may explain the observed differences in blood compatibility between the sulfonated polyurethanes based upon polyols of varying hydrophilicity.
引用
收藏
页码:735 / 745
页数:11
相关论文
共 24 条
[1]  
Andrade JD, 1985, SURFACE INTERFACIAL, P105, DOI DOI 10.1007/978-1-4684-8610-0_5
[2]  
Clark D.T., 1979, CHEM PHYSICS SOLID S, VII, P305
[3]  
DACOSTA VS, 1981, J COLLOID INTERF SCI, V80, P445
[4]   PROPERTIES AND BIOLOGICAL INTERACTIONS OF POLYURETHANE ANIONOMERS - EFFECT OF SULFONATE INCORPORATION [J].
GRASEL, TG ;
COOPER, SL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (03) :311-338
[5]   CHARACTERIZATION OF ALKYL GRAFTED POLYURETHANE BLOCK COPOLYMERS BY VARIABLE TAKEOFF ANGLE X-RAY PHOTOELECTRON-SPECTROSCOPY [J].
GRASEL, TG ;
CASTNER, DG ;
RATNER, BD ;
COOPER, SL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (05) :605-620
[6]   TECHNIQUE FOR CHARACTERIZATION OF HYDROPHILIC SOLID SURFACES [J].
HAMILTON, WC .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1972, 40 (02) :219-&
[7]   PROPERTIES OF POLYURETHANE ANIONOMERS - IONIZATION VIA BIMOLECULAR NUCLEOPHILIC DISPLACEMENT OF THE URETHANE HYDROGEN [J].
HWANG, KKS ;
SPECKHARD, TA ;
COOPER, SL .
JOURNAL OF MACROMOLECULAR SCIENCE-PHYSICS, 1984, B23 (02) :153-174
[8]  
Jr R.E., 1969, SURFACE COLLOID SCI, V2, P85
[9]  
Kajiyama T, 1991, J Biomater Appl, V6, P42, DOI 10.1177/088532829100600103
[10]   THE MEASUREMENT OF CONTACT ANGLES ON CIRCULAR TUBING SURFACES USING THE CAPTIVE BUBBLE TECHNIQUE [J].
LELAH, MD ;
GRASEL, TG ;
PIERCE, JA ;
COOPER, SL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (09) :1011-1015