TOTAL HIP-REPLACEMENT WITH SOLID AUTOLOGOUS FEMORAL-HEAD GRAFT FOR HIP-DYSPLASIA

被引:41
作者
HINTERMANN, B [1 ]
MORSCHER, EW [1 ]
机构
[1] UNIV BASEL, FELIX PLATTER HOSP, DEPT ORTHOPAED SURG, CH-4012 BASEL, SWITZERLAND
关键词
D O I
10.1007/BF00443387
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Acetabuloplasty with solid autologous femoral head graft for the treatment of hip dysplasia is an established method which creates the contained cavity needed to accommodate the artificial cup. In order to evaluate the medium- and long-term results of this method using a cementless hemispheric cup, 34 patients (39 hips) operated on between 1979 and 1986 were clinically and radiologically reviewed. The minimal follow-up was 5 years (average 7.6 years). The Harris hip score increased from 36 points preoperatively to 89 points 1 year postoperatively and to 85.1 at the last follow-up. On roentgenographic evaluation, all grafts had been incorporated and appeared to have tolerated the mechanical loading well. Partial resorption of the graft occurred in 22 of the 39 hips, mainly in the lateral non-loaded zone. Twenty-nine of the 39 acetabular components showed migration, on average 4.2 mm cranially and 1.8 mm medially; 92% occurred during the first 2 years, and thereafter it was not progressive. Smaller cups migrated consistently more than larger cups. A significant correlation was found between cup migration and the degree of bone coverage of the cup, and extensive migration occurred in most cases with cup coverage by the host bone of less than 40%-50% of the weight-bearing surface of the cup. Only one acetabular component was altered significantly, and another appears to have become loose. The use of normal-sized cups and cementless fixation medially in the primary acetabulum are thought to have contributed to our favorable mid- to long-term results. The substantial migration rate during the first 2 years was not related to loosening, and it did not continue to progress. Apparently, some migration must be accepted, and this does not necessarily correspond to cup loosening.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 57 条
[1]
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[2]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[3]
THE UNCEMENTED POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS - 2-YEAR RESULTS OF A PROSPECTIVE CONSECUTIVE SERIES [J].
CALLAGHAN, JJ ;
DYSART, SH ;
SAVORY, CG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :337-346
[4]
Carret J P, 1990, Acta Orthop Belg, V56, P387
[5]
STRESS DISTRIBUTIONS IN THE ACETABULAR REGION .2. EFFECTS OF CEMENT THICKNESS AND METAL BACKING OF THE TOTAL HIP ACETABULAR COMPONENT [J].
CARTER, DR ;
VASU, R ;
HARRIS, WH .
JOURNAL OF BIOMECHANICS, 1982, 15 (03) :165-170
[6]
TOTAL HIP-REPLACEMENT IN PATIENTS YOUNGER THAN 30 YEARS OLD - A 5-YEAR FOLLOW-UP-STUDY [J].
CHANDLER, HP ;
REINECK, FT ;
WIXSON, RL ;
MCCARTHY, JC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) :1426-1434
[7]
LOW-FRICTION ARTHROPLASTY IN CONGENITAL SUBLUXATION OF HIP [J].
CHARNLEY, J ;
FEAGIN, JA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1973, (91) :98-113
[8]
CONN R A, 1985, Orthopaedic Transactions, V9, P451
[9]
Cook S D, 1988, J Arthroplasty, V3, P249
[10]
COVENTRY MB, 1974, AAOS INSTR COURSE LE, V23, P136