OPTIMIZATION OF HIGH-SENSITIVITY FLUORESCENCE DETECTION

被引:119
作者
MATHIES, RA [1 ]
PECK, K [1 ]
STRYER, L [1 ]
机构
[1] STANFORD UNIV, MED CTR, SCH MED, DEPT CELL BIOL, STANFORD, CA 94305 USA
关键词
D O I
10.1021/ac00216a012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present general expressions for the number of photons emitted by a fluorescent chromophore as a function of the Intensity and the duration of illumination. The aim is to find optimal conditions for detecting fluorescent molecules In the presence of both ground-state depletion and photodestruction. The key molecular parameters are the absorption coefficient ϵ, the excited singlet-state lifetime τf the excited triplet-state decay rate kT, the intersystem crossing rate kI and the intrinsic photodestruction time τd. When only singlet saturation and photochemistry are important, the signal-to-noise ratio depends on two fundamental variables: k, the ratio of the absorption rate ka to the observed fluorescence decay rate kt and τ, the ratio of the duration of Illumination τ1 to the intrinsic photodestruction time τd. Equations are also developed for the more complicated cases when triplet formation and photochemistry are Important. This theory was tested by measuring the fluorescence from a solution of B-phycoerythrin flowed through a focused argon ion laser beam. The dependence of the fluorescence on the incident light intensity and the illumination time agrees well with the theoretical prediction for singlet saturation and photochemistry. The signal-to-noise ratio is optimal when the light intensity and the flow rate are adjusted so that both k and τ are close to unity (5 × 1022 photons cm−2 s−1 and a transit time τt of 700 µs). This analyste should be useful for optimizing fluorescence detection in DNA sequencing, chromatography, fluorescence microscopy, and single-molecule fluorescence detection. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:1786 / 1791
页数:6
相关论文
共 23 条
[1]   NON-RADIOACTIVE AUTOMATED SEQUENCING OF OLIGONUCLEOTIDES BY CHEMICAL DEGRADATION [J].
ANSORGE, W ;
ROSENTHAL, A ;
SPROAT, B ;
SCHWAGER, C ;
STEGEMANN, J ;
VOSS, H .
NUCLEIC ACIDS RESEARCH, 1988, 16 (05) :2203-2206
[2]   SUBATTOMOLE AMINO-ACID ANALYSIS BY CAPILLARY ZONE ELECTROPHORESIS AND LASER-INDUCED FLUORESCENCE [J].
CHENG, YF ;
DOVICHI, NJ .
SCIENCE, 1988, 242 (4878) :562-564
[3]   LASER-INDUCED FLUORESCENCE OF FLOWING SAMPLES AS AN APPROACH TO SINGLE-MOLECULE DETECTION IN LIQUIDS [J].
DOVICHI, NJ ;
MARTIN, JC ;
JETT, JH ;
TRKULA, M ;
KELLER, RA .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :348-354
[4]   A STABLE DOUBLE-STRANDED DNA ETHIDIUM HOMODIMER COMPLEX - APPLICATION TO PICOGRAM FLUORESCENCE DETECTION OF DNA IN AGAROSE GELS [J].
GLAZER, AN ;
PECK, K ;
MATHIES, RA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (10) :3851-3855
[5]   THE USE OF A CHARGE-COUPLED DEVICE FOR QUANTITATIVE OPTICAL MICROSCOPY OF BIOLOGICAL STRUCTURES [J].
HIRAOKA, Y ;
SEDAT, JW ;
AGARD, DA .
SCIENCE, 1987, 238 (4823) :36-41
[6]   QUANTUM EFFICIENCY INDEPENDENCE OF TIME INTEGRATED EMISSION FROM A FLUORESCENT MOLECULE [J].
HIRSCHFELD, T .
APPLIED OPTICS, 1976, 15 (12) :3135-3139
[7]   OPTICAL MICROSCOPIC OBSERVATION OF SINGLE SMALL MOLECULES [J].
HIRSCHFELD, T .
APPLIED OPTICS, 1976, 15 (12) :2965-2966
[8]   LUMINESCENCE DIGITAL IMAGING MICROSCOPY [J].
JOVIN, TM ;
ARNDTJOVIN, DJ .
ANNUAL REVIEW OF BIOPHYSICS AND BIOPHYSICAL CHEMISTRY, 1989, 18 :271-308
[9]   RAPID-FLOW RESONANCE RAMAN-SPECTROSCOPY OF PHOTOLABILE MOLECULES - RHODOPSIN AND ISORHODOPSIN [J].
MATHIES, R ;
OSEROFF, AR ;
STRYER, L .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1976, 73 (01) :1-5
[10]  
MATHIES RA, 1986, APPLICATIONS FLUORES, P129