COMPARATIVE-STUDY OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR THE DETERMINATION OF TETRACYCLINE ANTIBIOTICS

被引:20
作者
WHITE, CR
MOATS, WA
KOTULA, KL
机构
[1] USDA ARS,BELTSVILLE AGR RES CTR,BELTSVILLE,MD 20705
[2] UNIV DELAWARE,DEPT FOOD SCI,NEWARK,DE 19701
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1993年 / 16卷 / 13期
关键词
D O I
10.1080/10826079308019620
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work reviewed all the past HPLC methods utilized for the detection of tetracyclines and created a model to study the most promising ones. Three general mobile phases were investigated. They included Mobile Phase I (0.05 M buffer (A)-acetonitrile (B) programmed from 85A:15B to 40A:60B), Mobile Phase II (0.05 M buffer (A)-acetonitrile (B)-methanol (C) programmed from 80A:OB:20C to 30A:50B:20C), and Mobile Phase III (0.05 M buffer (A)-acetonitrile (B)-dimethylformamide (C) programmed from 80A:OB:20C to 30A:50B:20C). Buffers made from citrate, oxalate, and phosphate, each prepared at pH 2.0, 4.5, and 7.0, were used with each mobile phase. Ethylenediaminetetraacetic acid (EDTA) at 0.005 M was added to the pH 4.5 and pH 7.0 buffers (it would not dissolve in pH 2.0 buffers). Tetramethylammonium chloride (TMA) was also added at 0.01 M to all of the buffers at each pH. The columns chosen for this study were a C18 bonded to silica (Supelco LC-18), a ''deactivated'' C18 bonded column (Supelco LC-18-DB), and a polymeric styrenedivinylbenzene copolymer column (Polymer Laboratories PLRP-S). The columns and mobile phases were evaluated using a mixed standard of oxytetracycline, tetracycline, and chlortetracycline. Comparisons were based on peak shape, separations, and comparative recoveries (integrated areas) of standards. The polymeric column was markedly superior in all respects. Generally optimum results were obtained with Mobile Phase I in pH 2.0 buffers. The oxalate buffer was best with the bonded columns while little difference was noted with the polymeric column. TMA markedly improved peak shape on the bonded columns. EDTA was of little benefit. Recoveries, especially of chlortetracycline, were higher from the polymeric column.
引用
收藏
页码:2873 / 2890
页数:18
相关论文
共 47 条
[1]   DEGRADATION OF OXYTETRACYCLINE IN HONEY AS MEASURED BY FLUORESCENCE AND LIQUID-CHROMATOGRAPHIC ASSAYS [J].
ARGAUER, RJ ;
MOATS, WA .
APIDOLOGIE, 1991, 22 (02) :109-115
[2]   ANALYSES OF TETRACYCLINE ANTIBIOTICS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ASZALOS, A ;
HANEKE, C ;
HAYDEN, MJ ;
CRAWFORD, J .
CHROMATOGRAPHIA, 1982, 15 (06) :367-373
[4]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE ASSAY OF OXYTETRACYCLINE [J].
BARNES, WN ;
RAY, A ;
BATES, LJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (01) :173-178
[5]   DETERMINATION OF OXYTETRACYCLINE IN FISH BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BJORKLUND, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 432 :381-387
[6]   DETERMINATION OF CHLORTETRACYCLINE RESIDUES IN TISSUES USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
BLANCHFLOWER, WJ ;
MCCRACKEN, RJ ;
RICE, DA .
ANALYST, 1989, 114 (04) :421-423
[7]  
BOCKER R, 1979, ARZNEIMITTEL-FORSCH, V29-2, P1690
[8]  
BOTSOGLOU NA, 1984, CHIM CHRON, V13, P37
[9]  
CAPITANI F, 1985, B CHIM FARM, V124, P13
[10]   DOXYCYCLINE DETERMINATION IN HUMAN-SERUM AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DELEENHEER, AP ;
NELIS, HJCF .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1979, 68 (08) :999-1002