A COMPARATIVE-STUDY OF PCR PRODUCT DETECTION AND QUANTITATION BY ELECTROCHEMILUMINESCENCE AND FLUORESCENCE

被引:36
作者
YU, H
BRUNO, JG
CHENG, TC
CALOMIRIS, JJ
GOODE, MT
机构
[1] USA, EDGEWOOD RES DEV & ENGN CTR,SCBRD RTE,USAF, ARMSTRONG LAB,CBDCOM,CREW SYST DIRECTORATE AL CF, ABERDEEN PROVING GROUND, MD 21010 USA
[2] OPTECH CORP, SAN ANTONIO, TX 78229 USA
[3] SCI & TECHNOL CORP, EDGEWOOD, MD 21040 USA
来源
JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE | 1995年 / 10卷 / 04期
关键词
ELECTROCHEMILUMINESCENCE; MAGNETIC SEPARATION; DNA PROBES; PCR; QUANTITATION;
D O I
10.1002/bio.1170100407
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Amplification and detection of target DNA sequences are made possible in a polymerase chain reaction (PCR) by using a mixture of biotinylated and ruthenium(II) trisbipyridal (Ru(bpy)(3)(2+))-end-labelled primers. In this way, biotin for capture and RU(bpy)(3)(2+) for detection are directly incorporated into the PCR product obviating subsequent probe hybridization. PCR of a bacterial DNA template from Alteromonas species strain JD6.5 using a cocktail of biotin- and Ru(bpy)(3)(2+)-labelled primers amplified a 1 kilobase region. Serial dilution of PCR product followed by magnetic separation with Streptavidin (SA)-coated magnetic beads and an electrochemiluminescence (ECL) assay using the semi-automated QPCR System 5000 demonstrated sensitive (pg range) DNA detection. ECL assay of probe hybridization to a human immunodeficiency virus (HIV) sequence also produced pg level sensitivity. Quantitative DNA determination by ECL assay correlated well with visual detection of DNA in electrophoretic gels. However, DNA detection by ECL assay was 10 to 100 times more sensitive than conventional ethidium bromide staining. The combination of DNA-based magnetic separation with ECL assay provides a very sensitive and rapid method of quantitating DNA which, owing to its rapid and facile nature, may have many applications in the research, environmental monitoring, industrial and clinical fields.
引用
收藏
页码:239 / 245
页数:7
相关论文
共 11 条
[1]  
ANDREWS AT, 1991, ESSENTIAL MOL BIOL P, V1, P49
[2]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[3]   PURIFICATION AND PROPERTIES OF AN ORGANOPHOSPHORUS ACID ANHYDRASE FROM A HALOPHILIC BACTERIAL ISOLATE [J].
DEFRANK, JJ ;
CHENG, TC .
JOURNAL OF BACTERIOLOGY, 1991, 173 (06) :1938-1943
[4]  
DICESARE J, 1993, BIOTECHNIQUES, V15, P152
[5]   ELECTROGENERATED CHEMILUMINESCENCE - AN OXIDATIVE-REDUCTION TYPE ECL REACTION SEQUENCE USING TRIPROPYL AMINE [J].
LELAND, JK ;
POWELL, MJ .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1990, 137 (10) :3127-3131
[6]   DNA AMPLIFICATION FOR DIRECT DETECTION OF HIV-1 IN DNA OF PERIPHERAL-BLOOD MONONUCLEAR-CELLS [J].
OU, CY ;
KWOK, S ;
MITCHELL, SW ;
MACK, DH ;
SNINSKY, JJ ;
KREBS, JW ;
FEORINO, P ;
WARFIELD, D ;
SCHOCHETMAN, G .
SCIENCE, 1988, 239 (4837) :295-297
[7]  
Sambrook J., 1989, MOL CLONING LAB MANU
[8]  
TSURUTA H, 1994, J IMMUNOL METHODS, V176, P45
[9]   QUANTITATION OF POLYMERASE CHAIN-REACTION PRODUCTS BY HYBRIDIZATION-BASED ASSAYS WITH FLUORESCENT, COLORIMETRIC, OR CHEMILUMINESCENT DETECTION [J].
VLIEGER, AM ;
MEDENBLIK, AMJC ;
VANGIJLSWIJK, RPM ;
TANKE, HJ ;
VANDERPLOEG, M ;
GRATAMA, JW ;
RAAP, AK .
ANALYTICAL BIOCHEMISTRY, 1992, 205 (01) :1-7
[10]   COMPARISON OF 3 NONRADIOISOTOPIC POLYMERASE CHAIN REACTION-BASED METHODS FOR DETECTION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 [J].
WHETSELL, AJ ;
DREW, JB ;
MILMAN, G ;
HOFF, R ;
DRAGON, EA ;
ADLER, K ;
HUI, J ;
OTTO, P ;
GUPTA, P ;
FARZADEGAN, H ;
WOLINSKY, SM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (04) :845-853