HIGHER-ORDER SPECTRA BASED DECONVOLUTION OF ULTRASOUND IMAGES

被引:88
作者
ABEYRATNE, UR [1 ]
PETROPULU, AP [1 ]
REID, JM [1 ]
机构
[1] DREXEL UNIV,DEPT ELECT & COMP ENGN,PHILADELPHIA,PA 19104
关键词
D O I
10.1109/58.476550
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We address the problem of improving the spatial resolution of ultrasound images through blind deconvolution, The ultrasound image formation process in the RF domain can be expressed as a spatio-temporal convolution between the tissue response and the ultrasonic system response, plus additive noise, Convolutional components of the dispersive attenuation and aberrations introduced by propagating through the object being imaged are also incorporated in the ultrasonic system response, Our goal is to identify and remove the convolutional distortion in order to reconstruct the tissue response, thus enhancing the diagnostic quality of the ultrasonic image, Under the assumption of an independent, identically distributed, zero-mean, non-Gaussian tissue response, we were able to estimate distortion kernels using bicepstrum operations on RF data, Separate 1-D distortion kernels were estimated corresponding to axial and lateral image lines and used in the deconvolution process, The estimated axial kernels showed similarities to the experimentally measured pulse-echo wavelet of the imaging system, Deconvolution results from B-scan images obtained with clinical imaging equipment showed a 2.5-5.2 times gain in lateral resolution, where the definition of the resolution has been based on the width of the autocovariance function of the image, The gain in axial resolution was found to be between 1.5 and 1.9.
引用
收藏
页码:1064 / 1075
页数:12
相关论文
共 38 条
[1]  
ABEYRATNE UR, 1995, UNPUB IEEE T MED IMA
[2]  
ABEYRATNE UR, 1994, JUL SPIE INT S OPT I
[3]   MATHEMATICAL SIMULATION OF PRESSURE PULSE-PROPAGATION IN BIOLOGICAL TISSUES [J].
ADROV, VN ;
CHERNOMORDIK, VV .
ULTRASONIC IMAGING, 1993, 15 (01) :59-71
[4]   TRANSIENT FIELDS OF CONCAVE ANNULAR ARRAYS [J].
ARDITI, M ;
FOSTER, FS ;
HUNT, JW .
ULTRASONIC IMAGING, 1981, 3 (01) :37-61
[5]   BREAST MASS DETECTION BY US - A PHANTOM STUDY [J].
DAVROS, WJ ;
MADSEN, EL ;
ZAGZEBSKI, JA .
RADIOLOGY, 1985, 156 (03) :773-775
[6]   ULTRASONIC B-SCAN IMAGING - THEORY OF IMAGE-FORMATION AND A TECHNIQUE FOR RESTORATION [J].
FATEMI, M ;
KAK, AC .
ULTRASONIC IMAGING, 1980, 2 (01) :1-47
[7]   PHASE-ABERRATION CORRECTION USING SIGNALS FROM POINT REFLECTORS AND DIFFUSE SCATTERERS - BASIC PRINCIPLES [J].
FLAX, SW ;
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (06) :758-767
[8]   2-DIMENSIONAL ULTRASONIC BEAM DISTORTION IN THE BREAST - INVIVO MEASUREMENTS AND EFFECTS [J].
FREIBURGER, PD ;
SULLIVAN, DC ;
LEBLANC, BH ;
SMITH, SW ;
TRAHEY, GE .
ULTRASONIC IMAGING, 1992, 14 (04) :398-414
[9]   DIGITAL PROCESSING OF ULTRASONIC DATA BY DECONVOLUTION [J].
HUNDT, EE ;
TRAUTENBERG, EA .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1980, 27 (05) :249-252
[10]   DECONVOLUTION OF ULTRASOUND IMAGES [J].
JENSEN, JA .
ULTRASONIC IMAGING, 1992, 14 (01) :1-15