COMPARISON OF Z AND MULTIVARIATE STATISTICAL BRAIN ELECTROMAGNETIC MAPS FOR THE LOCALIZATION OF BRAIN-LESIONS

被引:16
作者
FERNANDEZBOUZAS, A
HARMONY, T
GALAN, L
MAROSI, E
FERNANDEZ, T
REYES, A
SILVA, J
RODRIGUEZ, M
BERNAL, J
ALONSO, M
机构
[1] HOSP JUAREZ MEXICO,MEXICO CITY,DF,MEXICO
[2] CTR NEUROCIENCIAS CUBA,HAVANA,CUBA
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1995年 / 95卷 / 05期
关键词
EEG MAPPING; BRAIN LESIONS; COMPUTED TOMOGRAPHY; CURRENT SOURCE DENSITIES; Z EEG MAPS; POWER SPECTRUM; FREQUENCY ANALYSIS;
D O I
10.1016/0013-4694(95)00111-B
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conventional Z maps provide probability statements about the deviation of observed values from the norm. Galan et al. (1994) introduced Simultaneous Significance Probability Scales to detect abnormalities over the whole map, making use of the information provided by the topographic structure of dependencies. They also described multivariate brain electromagnetic (MBE) maps for compact presentation of complex spatio-temporal information. In this paper, using the distance-based localization receiver operating characteristic curves (DL-ROC curves), we compare the localization provided by computed tomography with that provided by Z and MBE maps in 61 patients with brain lesions. Maps were calculated for absolute power and relative power in delta, theta, alpha and beta bands for voltage and current source densities (CSD). In each patient, all maps were compared and the map with the highest value of the area of the DL-ROC curve was considered to be the ''best map.'' Z maps of CSD were the ''best maps'' in 24 patients. In the voltage montage, we observed that multivariate maps add some information not contained in the Z maps. However, for CSD, Z maps were more accurate than multivariate maps. A very consistent finding was the observation that lesions were better detected by maps analyzing the delta band, while edema was better represented by maps in the theta range.
引用
收藏
页码:372 / 380
页数:9
相关论文
共 30 条
[1]   BRAIN ELECTRICAL-FIELD MEASUREMENTS UNAFFECTED BY LINKED EARLOBES REFERENCE [J].
ANDINO, SLG ;
MARQUI, RDP ;
SOSA, PAV ;
LIRIO, RB ;
MACHADO, C ;
DIAZ, G ;
RODRIGUEZ, PF ;
TORREZ, CC .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1990, 75 (03) :155-160
[2]  
BISCAY R, 1992, COMPUT BIOL MED, V22, P227
[3]  
DUFFY F H, 1990, Brain Topography, V3, P3, DOI 10.1007/BF01128856
[4]   THE BEAM METHOD FOR NEUROPHYSIOLOGICAL DIAGNOSIS [J].
DUFFY, FH .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1985, 457 :19-34
[5]   SIGNIFICANCE PROBABILITY MAPPING - AN AID IN THE TOPOGRAPHIC ANALYSIS OF BRAIN ELECTRICAL-ACTIVITY [J].
DUFFY, FH ;
BARTELS, PH ;
BURCHFIEL, JL .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1981, 51 (05) :455-462
[6]  
FERNANDEZBOUZAS A, 1993, BRAIN TOPOGR, V5, P438
[7]  
FISCHERWILLIAMS M, 1987, ELECTROENCEPHALOGRAP, P229
[8]  
Galan Lidice, 1994, Brain Topography, V7, P17, DOI 10.1007/BF01184834
[9]   TRANSFORMATIONS TOWARDS THE NORMAL-DISTRIBUTION OF BROAD-BAND SPECTRAL PARAMETERS OF THE EEG [J].
GASSER, T ;
BACHER, P ;
MOCKS, J .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1982, 53 (01) :119-124
[10]   QUANTITATIVE COMPARISON OF TRADITIONAL READING OF EEG AND INTERPRETATION OF COMPUTER-EXTRACTED FEATURES IN PATIENTS WITH SUPRATENTORIAL BRAIN LESIONS [J].
GOTMAN, J ;
GLOOR, P ;
RAY, WF .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 38 (06) :623-639