MEASUREMENT OF TIDAL VOLUME USING A PNEUMOTACHOMETER DURING HIGH-FREQUENCY OSCILLATION

被引:20
作者
COURTNEY, SE
WEBER, KR
SPOHN, WA
MALIN, SW
BENDER, CV
GOTSHALL, RW
机构
[1] WRIGHT STATE UNIV, DEPT PHYSIOL, DAYTON, OH 45435 USA
[2] CHILDRENS MED CTR, DIV NEONATOL, DAYTON, OH USA
[3] CHILDRENS MED CTR, DIV RESP THERAPY, DAYTON, OH USA
[4] WRIGHT STATE UNIV, DEPT PEDIAT, DAYTON, OH 45435 USA
[5] CHILDRENS MED CTR, DIV PULMONOL, DAYTON, OH USA
关键词
D O I
10.1097/00003246-199006000-00015
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To assess the accuracy of a pneumotachometer (PN) for tidal volume (VT) measurements during high-frequency oscillation (HFO), we determined simultaneously VT using a PN and a full body plethysmograph (PL) in 12 rabbits. HFO was delivered with an oscillator at a frequency of 10 Hz, mean airway pressure of 8 cm H2O, and inspiratory time of 50%. Pressure amplitude (ΔP) was varied as follows: 40, 60, 80, 20, 100, 40 cm H2O. Finally, in ten rabbits a spacer equal in deadspace (VD) to that of the PN (15 ml) was left in-line for 5 min. Blood gases were obtained before and after the spacer was added. We found that VT-PN correlates well with VT-PL (r = .92), although the difference between VT-PN and VT-PL is greater at large VT. Significant respiratory acidosis developed with the spacer in-line. PN may be used to trend VT during HFO but PN must not be left in-line, as increased VD seriously affects ventilation.
引用
收藏
页码:651 / 653
页数:3
相关论文
共 9 条
[1]  
BANCALARI A, 1988, BIOL NEONATE, V53, P61
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   GAS-EXCHANGE IN HEALTHY RABBITS DURING HIGH-FREQUENCY OSCILLATORY VENTILATION [J].
BOYNTON, BR ;
HAMMOND, MD ;
FREDBERG, JJ ;
BUCKLEY, BG ;
VILLANUEVA, D ;
FRANTZ, ID .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (03) :1343-1351
[4]   RANDOMIZED TRIAL OF HIGH-FREQUENCY JET VENTILATION VERSUS CONVENTIONAL VENTILATION IN RESPIRATORY-DISTRESS SYNDROME [J].
CARLO, WA ;
CHATBURN, RL ;
MARTIN, RJ .
JOURNAL OF PEDIATRICS, 1987, 110 (02) :275-282
[5]  
HIFI Study Group, 1989, N Engl J Med, V320, P88
[6]   MEASUREMENT OF TIDAL VOLUME DURING HIGH-FREQUENCY VENTILATION BY IMPEDANCE PLETHYSMOGRAPHY [J].
SANDBERG, KL ;
LINDSTROM, DP ;
KRUEGER, ED ;
SUNDELL, H ;
COTTON, RB .
PEDIATRIC RESEARCH, 1988, 23 (03) :253-256
[7]   EFFECTS OF FREQUENCY, TIDAL VOLUME, AND LUNG-VOLUME ON CO2 ELIMINATION IN DOGS BY HIGH-FREQUENCY (2-30 HZ), LOW TIDAL VOLUME VENTILATION [J].
SLUTSKY, AS ;
KAMM, RD ;
ROSSING, TH ;
LORING, SH ;
LEHR, J ;
SHAPIRO, AH ;
INGRAM, RH ;
DRAZEN, JM .
JOURNAL OF CLINICAL INVESTIGATION, 1981, 68 (06) :1475-1484
[8]  
SPOHN W A, 1988, Pediatric Research, V23, p569A
[9]   MEASUREMENT OF TIDAL VOLUME DURING HIGH-FREQUENCY JET VENTILATION [J].
WEISBERGER, SA ;
CARLO, WA ;
FOUKE, JM ;
CHATBURN, RL ;
TILLANDER, T ;
MARTIN, RJ .
PEDIATRIC RESEARCH, 1986, 20 (01) :45-48