ENTRANCE AND EXIT DOSE REGIONS FOR A CLINAC-2100C

被引:37
作者
KLEIN, EE
PURDY, JA
机构
[1] Mallinckrodt Institute of Radiology, Washington University Medical School, St. Louis, MO 63110
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1993年 / 27卷 / 02期
关键词
SURFACE DOSE; HETEROGENEITY; DOSIMETRY;
D O I
10.1016/0360-3016(93)90256-U
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: While significant advances have taken place in confirming dose in homogeneous media and accounting for changes due to distant heterogeneities, interface dosimetry is still a dose assessment problem. The entrance and exit surfaces of the patient are a prime example where dose assessment is questionable, but important, in many clinical situations. Methods and Materials: Data were taken to examine the effect of such parameters as field size, source-to-skin distance, blocking tray, compensation materials (lead, aluminum and brass) and various patient support materials (Mylar, graphite, thermal plastic, and foam) on the surface doses from a dual energy (6 MV, 18 MV) linear accelerator. Measurements were conducted with a thin window parallel-plate chamber. Results: Relative surface dose was found to have a proportional dependence on field size for both energies with surface doses ranging from 6% to 53%. A surface depth dose of 22.6% for a 15 cm field was measured for the low energy beam while a surface dose of 22.3% was observed for the 18 MV beam. The surface dose increased significantly for short source to skin distances and with the presence of a blocking tray. Compensating filter materials had little influence on surface dose. However, patient support devices such as Alpha Cradle and the graphite of the table can increase the surface dose to as much as 92%. Conclusion: We found there was a loss in dose at the exit surface (in comparison with percent depth dose tables, which assume infinite depth) on the order of 15% and 11% for the 6 MV and 18 MV beams, respectively. However, this loss is quickly compensated for with the introduction of most inherent backscattering media, [which in fact can increase the dose] for example, graphite in the patient support assembly tabletop.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 15 条
[1]  
CHAMBERLAIN EC, 1964, RADIOLOGY, V82, P267
[2]   X-RAY-BEAM CHARACTERISTICS OF THE VARIAN CLINAC 6-100 LINEAR-ACCELERATOR [J].
COFFEY, CW ;
BEACH, JL ;
THOMPSON, DJ ;
MENDIONDO, M .
MEDICAL PHYSICS, 1980, 7 (06) :716-722
[3]   VALIDITY OF TRANSITION-ZONE DOSIMETRY AT HIGH ATOMIC-NUMBER INTERFACES IN MEGAVOLTAGE PHOTON BEAMS [J].
DAS, IJ ;
KASE, KR ;
MEIGOONI, AS ;
KHAN, FM ;
WERNER, BL .
MEDICAL PHYSICS, 1990, 17 (01) :10-16
[4]   DOSIMETRY OF A DUAL PHOTON ENERGY LINEAR-ACCELERATOR [J].
FINDLEY, DO ;
FORELL, BW ;
WONG, PS .
MEDICAL PHYSICS, 1987, 14 (02) :270-273
[5]  
Gagnon W F, 1979, Med Phys, V6, P285, DOI 10.1118/1.594583
[6]  
GAGNON WF, 1973, RADIOLOGY, V117, P705
[7]   MEASUREMENT OF DOSE IN THE BUILDUP REGION USING FIXED-SEPARATION PLANE-PARALLEL IONIZATION CHAMBERS [J].
GERBI, BJ ;
KHAN, FM .
MEDICAL PHYSICS, 1990, 17 (01) :17-26
[8]   DOSIMETRY OF THE SIEMENS MEVATRON-67 LINEAR-ACCELERATOR [J].
HORTON, JL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (08) :1217-1223
[9]   A STUDY OF THE CHARACTERISTICS OF RADIATION CONTAMINANTS WITHIN A CLINICALLY USEFUL PHOTON-BEAM [J].
KRITHIVAS, G ;
RAO, SN .
MEDICAL PHYSICS, 1985, 12 (06) :764-768
[10]   INVESTIGATION OF BUILDUP DOSE FROM ELECTRON CONTAMINATION OF CLINICAL PHOTON BEAMS [J].
PETTI, PL ;
GOODMAN, MS ;
GABRIEL, TA ;
MOHAN, R .
MEDICAL PHYSICS, 1983, 10 (01) :18-24