THE USE OF NONRADIOACTIVE CHROMIUM AS AN ALTERNATIVE TO CR-51 IN NK ASSAY

被引:25
作者
BORELLA, P [1 ]
BARGELLINI, A [1 ]
SALVIOLI, S [1 ]
MEDICI, CI [1 ]
COSSARIZZA, A [1 ]
机构
[1] UNIV MODENA,DIPARTIMENTO SCI BIOCMED,PATOL GEN SEZ,I-41100 MODENA,ITALY
关键词
NONRADIOACTIVE LABELING; ATOMIC ABSORPTION SPECTROSCOPY; CYTOTOXICITY ASSAY; NATURAL KILLER CELL; CHROMIUM CELL TOXICITY; MITOCHONDRIAL MEMBRANE POTENTIAL;
D O I
10.1016/0022-1759(95)00140-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method to measure target cell cytolysis based on the use of 'cold', non-radioactive chromium and on the determination of metal release by graphite furnace atomic absorption spectroscopy (FAAS) is proposed. Natural killer (NK) assays were performed by labelling target cells with chromium as Na2CrO4, and results were compared with those obtained by conventional overnight labelling with Cr-51 of targets killed by the same effecters. The cytotoxic capacity of peripheral blood lymphocytes from healthy subjects was evaluated, and NK activity measured with both methods showed a good agreement at each of the tested effector to target cell ratios (between 100:1 and 1:1), with a high and significant coefficient of correlation (r = 0.931, p < 0.0001). The selection of the appropriate Cr concentrations for labelling target cells took into account both the sensitivity of our instrumentation and the possible toxic effects of the metal. A study of the effects of Cr on the cell line (K562) which is usually employed as a target in NK tests showed that Cr could have a detrimental effect on cellular function, with significant numbers of cells with depolarised mitochondria and reduced DNA synthesis after 24 h incubation using Cr levels higher than 15 mu mol/l (780 mu g/l). The method proposed here has a number of advantages, including the use of a non-radioactive tracer, limited costs, high sensitivity and reproducibility, and the possibility of storing samples. In addition, the technique uses a fixed Cr concentration which is known to be non toxic.
引用
收藏
页码:101 / 110
页数:10
相关论文
共 33 条
[1]   DIETARY-FAT AND NATURAL-KILLER-CELL ACTIVITY [J].
BARONE, J ;
HEBERT, JR ;
REDDY, MM .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1989, 50 (04) :861-867
[2]   EUROPIUM-LABELED TARGET-CELLS IN AN ASSAY OF NATURAL-KILLER CELL-ACTIVITY .2. A NOVEL NONRADIOACTIVE METHOD BASED ON TIME-RESOLVED FLUORESCENCE - SIGNIFICANCE AND SPECIFICITY OF THE METHOD [J].
BLOMBERG, K ;
GRANBERG, C ;
HEMMILA, I ;
LOVGREN, T .
JOURNAL OF IMMUNOLOGICAL METHODS, 1986, 92 (01) :117-123
[3]   LEAD AND CADMIUM AT VERY LOW-DOSES AFFECT INVITRO IMMUNE-RESPONSE OF HUMAN-LYMPHOCYTES [J].
BORELLA, P ;
GIARDINO, A .
ENVIRONMENTAL RESEARCH, 1991, 55 (02) :165-177
[4]  
BORELLA P, 1990, J TRACE ELEM ELECT H, V4, P87
[5]  
BORELLA P, 1993, J TRACE ELEM ELECT H, V7, P231
[6]   DETERMINATION OF CYTOTOXIC LYMPHOCYTE-T PRECURSOR FREQUENCIES USING EUROPIUM LABELING AS A NONRADIOACTIVE ALTERNATIVE TO LABELING WITH CHROMIUM-51 [J].
BOUMA, GJ ;
VANDERMEERPRINS, PMW ;
VANBREE, FPMJ ;
VANROOD, JJ ;
CLAAS, FHJ .
HUMAN IMMUNOLOGY, 1992, 35 (02) :85-92
[7]   AUTOMATED FLUOROMETRIC ASSAY FOR T-CELL CYTO-TOXICITY [J].
BRENAN, M ;
PARISH, CR .
JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 112 (01) :121-131
[8]   CARBOXYFLUORESCEIN FLUOROCHROMASIA ASSAYS .1. NON-RADIOACTIVELY LABELED CELL-MEDIATED LYMPHOLYSIS [J].
BRUNING, JW ;
KARDOL, MJ ;
ARENTZEN, R .
JOURNAL OF IMMUNOLOGICAL METHODS, 1980, 33 (01) :33-44
[9]  
BRUNNER KT, 1968, IMMUNOLOGY, V14, P181
[10]   VIABILITY MEASUREMENTS IN MAMMALIAN-CELL SYSTEMS [J].
COOK, JA ;
MITCHELL, JB .
ANALYTICAL BIOCHEMISTRY, 1989, 179 (01) :1-7