HIGH-PURITY FACTOR-IX CONCENTRATES FOR TREATMENT OF HEMOPHILIA-B - RELATIVE PURITY AND THROMBOGENIC POTENTIAL

被引:18
作者
LIMENTANI, SA
GOWELL, KP
DEITCHER, SR
机构
[1] Center for Hemostasis and Thrombosis Research, Division of Hematology and Oncology, Department of Medicine, New England Medical Center Hospitals, Tufts University School of Medicine, Boston, MA
关键词
CONTAMINANTS; HEMOPHILIA B; HIGH-PURITY FACTOR IX CONCENTRATES; THROMBOTIC COMPLICATIONS; VITAMIN-K-DEPENDENT PROTEINS;
D O I
10.1159/000204023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Constituents other than factor UC have been implicated as etiologic agents for thrombotic complications in patients receiving prothrombin complex concentrates (PCCs). In vitro studies, in vivo animal models, and clinical evaluations in patients with hemophilia B indicate that high-purity factor IX concentrates contain significantly fewer potentially thrombogenic contaminants than PCCs. A recent in vitro study from our laboratory used highly sensitive assays to analyze the relative purity of these newer products. The following products were studied using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) analysis and immunoblotting: Aimafix, AlphaNine-SD, Factor IX VHP, Immunine, Mononine, Nanotiv, and 9MC (now known as Replinine). The mean specific activity of the high-purity factor M products ranged from 68 IU factor IX/mg (Aimafix) to 246 IU factor IX/mg (Mononine). SDS-PAGE analysis under reducing and nonreducing conditions showed that Mononine had the fewest contaminating bands. The immunoblot to detect factor IX showed a dominant factor IX band for all products, visible Light chain of factor IX for all products except Aimafix, and another contaminating band visible at 49,500 daltons for all products except 9MC. High molecular weight contaminants were apparent for some products. Factor VIIa was detected in some lots of Immunine, Nanotiv and 9MC. Factor X and prothrombin contaminated Aimafix, AlphaNine-SD, Factor IX VHP, Immunine, Nanotiv and 9MC. Thus, Mononine, Nanotiv and 9MC demonstrated the highest purity but no product was totally free of contaminants.
引用
收藏
页码:12 / 17
页数:6
相关论文
共 23 条
  • [1] BERNTORP E, 1993, THROMB HAEMOSTASIS, V70, P768
  • [2] PROPERTIES OF A HIGHLY PURIFIED HUMAN-PLASMA FACTOR-IX-C THERAPEUTIC CONCENTRATE PREPARED BY CONVENTIONAL CHROMATOGRAPHY
    BURNOUF, T
    MICHALSKI, C
    GOUDEMAND, M
    HUART, JJ
    [J]. VOX SANGUINIS, 1989, 57 (04) : 225 - 232
  • [3] GILES AR, 1982, BLOOD, V59, P401
  • [4] REDUCED COAGULATION ACTIVATION FOLLOWING INFUSION OF A HIGHLY PURIFIED FACTOR-IX CONCENTRATE COMPARED TO A PROTHROMBIN COMPLEX CONCENTRATE
    HAMPTON, KK
    PRESTON, FE
    LOWE, GDO
    WALKER, ID
    SAMPSON, B
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1993, 84 (02) : 279 - 284
  • [5] HERRING SW, 1993, J LAB CLIN MED, V121, P394
  • [6] HRINDA ME, 1991, SEMIN HEMATOL, V28, P6
  • [7] KASPER CK, 1973, NEW ENGL J MED, V289, P160
  • [8] THROMBOEMBOLIC COMPLICATIONS
    KASPER, CK
    [J]. THROMBOSIS ET DIATHESIS HAEMORRHAGICA, 1975, 33 (03): : 640 - 644
  • [9] KIM HC, 1992, BLOOD, V79, P568
  • [10] KIM HC, 1991, SEMIN HEMATOL, V28, P15